Search results

  1. C

    Rebuilding an old chimney stack

    Thanks for your reply Johnny 2007 I am a little surprised that the quote didn't mention replacing lead flashing. If this is the case I feel this quote is on the high side from your quote.
  2. C

    Rebuilding an old chimney stack

    Hi the quote says to take down the stack to flashing level and rebuild therefore I would not replacing flashing. This certainly wasn't detailed in the quote . Thanks
  3. C

    Rebuilding an old chimney stack

    I have noticed some penetrating damp from inside parents bedroom. After investigation we have found this damp to be probably coming from a corroded chimney stack. We have had an estimate to rebuild the stack with the existing bricks. The estimate from this work (builder says it will take 2 men...
  4. C

    Boiler flue into carport

    Thanks for comments on this gone round the houses a few times and spoken to as many "experts" as I could find . The general consensus from gas central fitters is fitting a boiler flu under a canopy is a no no. Spoke to Baxi technical team who were more concerned about possible damage done to...
  5. C

    Boiler flue into carport

    Thanks for the picture Ian on the plume management kit installed, did you discharge the flu through the roof of the car port (IE need to remove a section of the roof)
  6. C

    Boiler flue into carport

    Thanks for the comment. So to make it clear to me the plume kit moves this slightly acidic vapour to a point higher up in the port. Would the car still be able to go into the port and would it affect neighbours adjoining port which would be approx 3m from the discharge of the plume management kt.
  7. C

    Boiler flue into carport

    Ok so basically the pluming is not stopped but moved somewhere it is less of an issue ? Thanks
  8. C

    Boiler flue into carport

    I would definitely use a gas safe engineer to fit plume deflector kit. This could well be the answer to my problem. Does anyone know how good these kits are and do they stop all pluming ?
  9. C

    Boiler flue into carport

    Hi Chris, just read page 20 of manufactures instructions where flu can discharge into a car port but a flu displacement kit is recommended, any idea of the cost of one of these kits ?
  10. C

    Boiler flue into carport

    Thanks Chris, that was my thoughts to. If have had two gas engineers round both would like to put holes through the porch roof which I would like to avoid at all costs. Any thoughts where I can get any info from to verify to the engineers that it should be ok to discharge flu into car port as...
  11. C

    Boiler flue into carport

    Hi boiler is Baxi Combi 40 Platinum.
  12. C

    Boiler flue into carport

    I need to move my combi boiler from its present location . One area I would like to consider moving to is a large pantry type cupboard. One issue I have come across is that the boiler flu would discharge into a 3 open sided car port. Can anyone give me any information on whether a combi boiler...
  13. C

    Help on Christmas Eve Eve

    Help my daughter has a 18 month old toddler and the washing machine has started to play up on Christmas Eve Eve. Symptoms ,machine will not drain fully, coming up with E21 code. Filter has been removed and cleaned discharge pipework stripped and clear. Machine is Logik L612WM16 approx 8 months...
  14. C

    Continual boiler problems

    Thanks for the advice picasso this boiler operates intermittently and can work sometimes for 20 mins I would guess that the pump either works or it doesn't or is that a very simplistic view .
  15. C

    Continual boiler problems

    Anyone any idea of how Baxi cost for repair do they cost for call out etc ?
  16. C

    Continual boiler problems

    Thanks for your replies Ian and Hanson I will mention getting Baxi on board and your comments are a reassurance that the boiler can be repaired then we can plan to replace the boiler at a convenient time to all
  17. C

    Continual boiler problems

    Thanks Ian I will check out the Baxi repair website. Would you agree we probably dont need a system flush as the CH water is clear almost looks as clean as tap water and no signs of sludge. We keep having power flushes mentioned to us
  18. C

    Continual boiler problems

    Thanks for the reply Ian. They have a Baxi combi 80e. The boiler fires up as normal then on both CH and direct water supply heats up and boiler quickly moves up its temperature range before tripping out showing flashing 80+ deg. We have had the PCB replaced lasted about 2 weeks then the same...
  19. C

    Continual boiler problems

    keep having issues with daughters baxi combi boiler to a point where we are thinking about replacement. A number of the quotes we received also mention wanting to do a central heating system flush. Drained some of the water from the base of a radiator the water was very clean with no signs of...
  20. C

    Intermittent Baxi combi fault

    Any advice gratefully accepted daughters Baxi combi fires up ok but then locks itself off without getting central heating hot. Does this a number of times then eventually stays on and keeps central heating warm. It appears that central heating water temperature has no control at the boiler...