  1. dilalio

    Stop Valve Caps

    I don't like them anywhere! I always use the butterfly handle ones on hot and cold feeds now. Less likely to be butchered by someone using the wrong screwdriver (or butter knife!) in a panic. But not on heating!
  2. dilalio

    Stop Valve Caps

    Ballofixs leak when actuated about 7 times out of 10. I always either remove or replace them. Only full bore isolators (lever) should be used on heating. Sometimes they can be made to stop with a bit of a technique when opening/closing them. Hard to describe but it involves changing the...
  3. dilalio

    Central Heating Only Coping With Heating 3 or 4 radiators

    Very simple first steps... Is boiler producing enough heat? Is that heat getting away from the boiler? If abv is passing return will get instantly warm back to boiler.
  4. dilalio

    No hot water

    Sounds very much like air in the coil to me. Especially seeing as you've recently had a powerflush.
  5. dilalio

    WTAF are these called???

    All hail Caesar ;)
  6. dilalio

    WTAF are these called???

    Amabay no good any more. Searches bring up any number of obscure results, just to get you to click click through. Screwfix website not much better. Drives me nuts.
  7. dilalio

    External cold feed

    Bushey mate.
  8. dilalio

    External cold feed

    I still can't visualise it! Never could see things in words when a sketch says a 1000! Can you pop a sketch up? Or, I can and see if we're thinking along the same lines. I'm thinking, cutting the 90 open has got to be big enough to fit the soldered pipe and the mitred insulation into it...
  9. dilalio

    External cold feed

    Reckon that would look the best. But still thinking how you'd glue the rwp 90s back up in an easy way? One cut and prise it apart or cut in half and glue thin edges back together? Can you get a rwp Tee?
  10. dilalio

    External cold feed

    Would that potentially heat the water inside the pipe?
  11. dilalio

    External cold feed

    Cheers. Just thinking how I would handle 90s and a tee! Inside the ducting?
  12. dilalio

    External cold feed

    It's not a domestic setup mate. It's a trust site for assisted living. Bit like a centerparcs for those needing 24hr care but some independence. The kitchens have been fully fitted and tiled etc, single storey building with vaulted ceilings so no loft space. Full patio and landscaping...
  13. dilalio

    External cold feed

    Have to run new cold mains from plant room to kitchen for potable water at kitchen sink. Previously the kitchen was used as a utility room and only had "grey" water supply to cold at sink. Now been converted to kitchen and also another kitchen backing on to it and has to have potable water...
  14. dilalio

    Few big issues in shower

    Do you want me to send you a few of them? Big Boy! xxx
  15. dilalio

    Few big issues in shower

    Workmanship is usually a 1 year guarantee from install. If it fails past that then something else is afoot.
  16. dilalio

    Weather compensation on old single pipe system

    Weather comp is, in essence, a method of referencing a temperature, that is external and is used to minimise over and under-shooting desired, internal target temperatures. As long as the curves are set correctly, it should provide better internal comfort temperatures as it will prevent...
  17. dilalio

    Powerflush, yes or no?

    And one that's connected on the CH. ;)
  18. dilalio

    Powerflush, yes or no?

    Get yourself a test kit.
  19. dilalio

    Inline Water Filter - to Fridge... flows slow!

    I've never had this problem with American fridges so, IMO it has to be with what what you've bought and are buying!
  20. dilalio

    Repair and decorate RSJs

    You may well be correct, hence the thickness of the coating!