  1. M

    Ravenheat CS1 85 CH Turns itself on, then overheats

    Is the "hot water switch" the microswitch that is part of the three way diverter valve. If so, could it be the valve pin that is sticking? Thanks.
  2. M

    Ravenheat CS1 85 CH Turns itself on, then overheats

    Sorry for the ignorance, but is the hot water switch the main DHW and CH reset switch located at the font of the boiler? Thanks.
  3. M

    Ravenheat CS1 85 CH Turns itself on, then overheats

    If the switch is at fault, would this turn on the CH if the timer is off and the room stat is at its lowest?
  4. M

    Ravenheat CS1 85 CH Turns itself on, then overheats

    Ravenheat CS1 85 I have a problem with the CH starting up on its own then overheating. The problem started with the DHW temperature fluctuating so I replaced the DHW thermistor sensor. This fixed the DHW problem. Last night I isolated the timer clock just leaving the room stat wired up to...