Search results

  1. P

    Installing Just Trays JT40 Fusion Shower Tray

    Thanks Madrab. So something like CT1 or Stixall to stick down the tray? I'm thinking if I put some on the flat spots on the bottom of the tray..for example where the legs would go that would do? The bottom of the tray is not totally flat....it has mouldings on it..I think to incorporate the...
  2. P

    Installing Just Trays JT40 Fusion Shower Tray

    Hi All, I'm about to install a 1100 x 900 JT40 stone resin shower tray into a 3 sided alcove. I've strengthened and leveled the joists and installed an 18mm Marine Ply base. It is dead level. I've put the tray in place to test/find location of waste and the tray is still level in all...
  3. P

    Grant Vortex Pro - Pressure Relief Valve dripping

    Yes there is a TMC factory set st 50c. Big sticker on it saying do not adjust so I've never touched it
  4. P

    Grant Vortex Pro - Pressure Relief Valve dripping

    Thanks for all the replies so far guys. So I checked the expansion vessel this morning. Seems OK. Static pressure holding at 1Bar. PRV hasn't dripped since yesterday and I've been checking the pressure gauge regularly and it seems steady (about 1.2 bar and goes up a bit after hot water store...
  5. P

    Grant Vortex Pro - Pressure Relief Valve dripping

    Hi, I've got a Grant Vortex Pro combi installed in 2017. I've just noticed that the out let pipe from the PRV is dripping. I've had a plastic bag over it to see how much it is dripping and I would say its a couple of teaspoons over the past 5 hours. Central heating hasn't been on since...
  6. P

    Grant Vortex Pro Combi 26 - Gurgling Air noise on Direct Hot Water side

    Thanks for the responses guys. Just as an update: I have had the central heating off for the past few days and the air in the store has been expelled and the boiler is behaving itself. I think that some air in the central heating made its way to the store after it came on for the first time...
  7. P

    Grant Vortex Pro Combi 26 - Gurgling Air noise on Direct Hot Water side

    Thanks Exedon. That is interesting about the newer models. I've just looked at the manual on the Grant website and can see the new version has several manual vent points now! There still seems to be an AAV on primary heat store on the new model. Is it possible/advisable to change that to a...
  8. P

    Grant Vortex Pro Combi 26 - Gurgling Air noise on Direct Hot Water side

    Hi All, I posted on this subject back in 2018 and never really got to the bottom of it! But I have an issue where air seems to be trapped in the heat store/exchanger on the hot water side of things. It fizzes and gurgles, knocks and bangs in various degrees of loudness and frequency. At the...
  9. P

    Is this a water vapor/condensation risk? Dwarf wall void in loft.

    Thanks catlad. That was my initial assumption too. It was when I was putting on the Mass Loaded Vinyl I started to think twice. Perhaps I am over-thinking it.
  10. P

    Is this a water vapor/condensation risk? Dwarf wall void in loft.

    Hi, I have been slowly upgrading a converted loft in my victorian semi. A couple of years ago I replaced the insulation in the rafters with PIR board. 100mm in between the rafters, 25mm underneath the rafter. 50mm gap between insulation in the rafters and batten for ventilation. At the...
  11. P

    T&G Chipboard Flooring - Do end joints need to be staggered?

    The boards are being laid at right angles to the joists but there is no way to align the boards so that the end of the board always lands on a joist. Even if I use an off-cut of board to start the row, there is no way lay the next two boards so that the end of each board can butt together over...
  12. P

    T&G Chipboard Flooring - Do end joints need to be staggered?

    Hi All, I am currently re-boarding my loft after lifting old chipboard to put down insulation. I am using 22mm P5 T&G Caberfloor boards. 2400mm x 600mm. The floor was previously strengthened and levelled by running 3x2 joists at right angles across the top of the existing 4x2 joists. The...
  13. P

    Grant Vortex Pro Combi 26 - Gurgling Air noise on Direct Hot Water side.

    Thanks Bob. Just to confirm, do you mean completely remove the AAVs and then put the old AAVs back on after filling?
  14. P

    Grant Vortex Pro Combi 26 - Gurgling Air noise on Direct Hot Water side.

    Hi All, I have a Grant Vortex Pro Combi 26 which is generally performing well but has a strange problem with a gurgling/fizzing/knocking noise when the Direct Hot Water pump is circulating. The central heating side is all nice and quiet. At first I thought the hot water was being over-heated...
  15. P

    Condensation on Breathable felt

    I found that by getting air into loft by moving the insulation back from the soffit area worked. Its been just as cold as it was last winter and I've had zero problems this year. So I guess what I'm telling you is that you need to check the ventilation in the roof - if you cant make some...
  16. P

    Condensation on Breathable felt

    I too have had success! Took a look up there yesterday and it is starting to dry out nicely. Am going to put the insulation back but cut it to size so that the eaves dont get blocked up again.
  17. P

    Condensation on Breathable felt

    There has been snow and Ice on the roof - as it is the cold side of the house it doesnt get a chance to melt off at the moment. The condensation has coincided with the bad weather. I think that ventilation from the soffits should be the cure as although the condensation hasnt gone yet ( it...
  18. P

    Condensation on Breathable felt

    datarebal, you seem to know your stuff. Is there any problem with increasing the ventilation in the roof and essentially treating my breathable felt as if it was a non breathable felt?
  19. P

    Condensation on Breathable felt

    weaviestevie - My felt has just a load of white gridlines on it, have been trying to look for images on the web cant find any clue as to what brand it is - does anyone know? I dont have any specific vent holes but do get a breeze coming through the soffits. When the roof was finished I...
  20. P

    Condensation on Breathable felt

    Hi Guys, thanks for the replies. I've got the full 270mm of insulation; 100mm between the rafters and 170mm over lapping at right angles. The room below is really quite warm considering the radiator is never on and window is always ajar. Just to update you, I've just been in to check the...
Back