Search results

  1. D

    Y plan no heating

    Doh To slow typing my reply
  2. D

    Y plan no heating

    Certainly sounds as if the diodes/resistors are causing the issue
  3. D

    Garden room patio door lintel?

    As Tony, even with snow load of 75kg/m2 and roof load of 50kg/m2 you are well within accepted parameters for allowable bending moment and deflection (actual 4mm with snow, 2mm without)
  4. D

    Only get central heating if hot water turned off (Ed.)

    Cannot say definitely but sounds as if the actuator is buggered which unfortunately for you may mean major plumbing work to replace, I just replaced mine which fortunately was a Drayton 3 port valve which meant I could just simply replace by removing the complete actuator box off the valve by...
  5. D

    Only get central heating if hot water turned off (Ed.)

    Have you looked under the box there should be a lever that comes across. When nothing working it should be in its rest position, there is a spring inside that pulls it to this rest position. When you are just asking for hot water it should remain in its rest position. When you are just asking...
  6. D

    Fill and expansion tank getting hot

    Same place as it says it was over pumping I guess ,but cutting the pipe has stopped it from doing so for some strange reason so all is good?
  7. D

    loft hatch conversion

    This is what I did many years ago and its worked OK for me for me forage into the loft several times a year The sliding cover is topped with insulation board and when its is pulled into position rests on foam insulation strip to prevent moisture/heat migrating into the roof space. The holding...
  8. D

    Fill and expansion tank getting hot

    But is not over pumping so is not an issue?
  9. D

    Boiler overheat trips when it gets cold out (Potterton Profile) (Ed.)

    Perhaps turn your room thermostat down so the boiler stops firing up for as long, depends whether your stat is in an area where a cooler control temperature is acceptable
  10. D

    Boiler overheat trips when it gets cold out (Potterton Profile) (Ed.)

    Surely the flame does cut out when it gets to 5 and the pump carries on circulating the hot water. Have you tried running it at 4
  11. D

    Removing immersion heater

    And did it leak? :-)
  12. D

    Removing immersion heater

    Could try one of these although when I tried one a few years ago it was everso slightly to big so I bottled the job and took it back https://www.toolstation.com/dickie-dyer-heavy-duty-immersion-heater-spanner/p62043
  13. D

    outhouse/garage low water pressure idea

    Are you saying there is hot and cold feed to the out houses? If so would it be possible to switch over the supplies at the house. It may mean waiting a longer for your hot water to arrive but may stop the WM locking out. Just a thought!!
  14. D

    Joist notched too much?

    Whats the joist connecting to it under the tape DeWalt sign doing?
  15. D

    Crack in corner of old extension and crack outside

    Nothing to sort except rake out and make good both faces
  16. D

    Pressure loss calculators

    Yes as there are 2 circuits does each has its own pump or is it some how split off, if its split off then depending on the frictional resistance of each circuit will depend how much of the flow each circuit takes. The frictional resistance of each circuit depends on length of pipework, number of...
  17. D

    Can I pipe basin waste into toilet flush pipe?

    so how often is the sink used, whats wrong with dumping water on the lawn as long as its not kitchin sink greasy stuff
  18. D

    Can I pipe basin waste into toilet flush pipe?

    Wow thats so far out the question never even registered, perhaps he can just loop the waste pipe over the seat and just be careful when he sits down
  19. D

    Can I pipe basin waste into toilet flush pipe?

    No issue whatsoever did it to my wc and wash basin 8 years ago with one of these