    Radiator valve crush reducers.

    They sell long 15mm by 10mm reducers end feed of solder ring there long enough to go into standard 15mm valves then onto your 10mm pipe. https://directplumbingsupplies.com/product/15mm-x-10mm-end-feed-long-tail-fitting-reducer
  2. O

    Levelling Spacer question

    Just be careful there's no mortar exess as it may stop your next row going in on the right spacing. I've just used the spinners but I think I prefer the wedges. As the spinners snap the clip. If you really torque them up.
  3. O

    Shower Niche estimate estimate

    How the hell are they going to. Build a niche so small. In height 150mm? Tanking one of my niches atm
  4. O

    Toilet waste blocking up

    First thing is to look in the first manhole and see if your drains are blocked
  5. O

    Tiling behind log burner help

    I looked at brickslips and lime rendering but by far the cheapest and fastest thing to do is dot and dab cement board then sheet up and spray it all with vht spray paint make sure you have a respirator on though. My front edge is easy fill where it meets the cement board been in two years had no...
  6. O

    Priming with Bond It SBR

    Acrylic sealer on walls. Sbr on back of porcelain or stone. I also mix my sbr with dry cement
  7. O

    Slab Laid, How long for foot traffic and shuttering off?

    Depends on the concrete was it volumetric or mixer lorry or mixed up on site with a small mixer? The first two will have far too much water in them and take longer to set and harden. Most of slabs I've done by hand 3 ton 9 " rebar for my garage was about 3-4 days.
  8. O

    Is it worth adding additional cores when buying SWA?

    I had 42mtrs of 16mm swa run down to my garage. Had a 100 amp. Cu in there with a 16amp socket for my inverter tig welder. Ran the wifi down the armored with a tplink main plug worked a treat.
  9. O

    Crosswater 3 way thermostatic valve- 90 mins to run a bath

    Get a new cartridge then pull out old one with pump grips I had same valve it's very prone to limescale blockage on the screens. I manged to get a cartridge out of crosswater free of charge...
  10. O

    Replacing a Danfoss HPA2 (4 wire??) motorised valve

    On the Drayton!! Not so if you go honeywell!
  11. O

    Recorded DVDs won't play on new machine.

    Get an old yamada dvd player of Ebay they will play literally everything and anything
  12. O

    Quote for UFH combi boiler work

    Each two port gives independent control. You you can have radiators on there own. Or ufh on it's own or both together. The only caveat is during hot water production you get neither.
  13. O

    Constant sludge

    Non barrier pipe used?
  14. O

    grohe concealed cistern

    I wouldn't worry about flexi. That just a bit of waterborne gunge of the water. Bit of bacterial growth in hot weather etc.
  15. O

    Glow Worm 25C Dripping

    Think that's plastic hose connected onto auto air vent inside
  16. O

    grohe concealed cistern

    Merchants unlikely to have one like that better getting on ebay or fixthebog
  17. O

    Quote for UFH combi boiler work

    Well to give you an idea. I did a extension underfloor job few months ago. Single zone 120 mtr roll of polypipe ultra flexible pipe, clipped down. 25/60 pump. On a single zone mixing valve. With a 2 port valve wired up to a heatmiser prt v4 programmable roomstat. Roll of edge surround pinned...
  18. O

    central heating from a log burner

    That setup would definately invalidate any household insurance you probably don't even have. Wet boilers for logburners are a very specific hetas ticket.