  1. J

    Worcester Greenstar junior - no CH

    Ok I fixed the issue and I have to say it’s completely embarrassing!! Part of me didn’t want to put the solution up here because it makes me look like a right numpty, but sod it, it might help someone else who makes the same mistake with out realising! Ok so here it is…. My radiators/pipes...
  2. J

    Worcester Greenstar junior - no CH

    Ok a pretty sure it’s not the diverter valve as it seems to be moving up and down ok. When I call for hot water it goes all the way up, the burner light comes on and stays on and the water is lovey and hot. When I turn the nest thermostat on, the diverter valve goes down to the bottom, then the...
  3. J

    Worcester Greenstar junior - no CH

    Cheers will give that a go tomorrow
  4. J

    Worcester Greenstar junior - no CH

    To be more specific it’s the green burner indicator light. It’s 100% a combi
  5. J

    Worcester Greenstar junior - no CH

    Combi boilers has packed up again. Hot water is absolutely fine, but no CH. Am thinking it’s possibly the diverter valve, although I only changed that 4-5 years ago, and am pretty sure that last time it was the other way round with CH working fine but with no hot water. When I call for hot...
  6. J

    Fan light fault?

    Thanks, so I literally just connect one wire to the live and one wire to neutral inside the light fitting and that’s it?
  7. J

    Drain off valve on radiator not fitting right

    Thanks, just tried it with about 10-12 wraps and seems to be a lot better now. Cheers
  8. J

    Drain off valve on radiator not fitting right

    I’m just about to fit some new radiators and I’ve purchased some of these Drayton drain off valves to place in front of the lock shields. https://www.screwfix.com/p/drayton-15mm-compression-x-1-2-bsp-male-taper-drain-off-tail-piece-50mm-polished-chrome/3450R I haven’t applied any PTFE yet but...
  9. J

    Fan light fault?

    Thanks, I must admit I’d never heard of a snubber before! Is this what you mean? https://amzn.to/4dfTa1V When you say, “fit across”, do I just connect one to live and one to neutral? Thanks
  10. J

    Fan light fault?

    I recently installed a new fan light in the second bedroom purchased from Amazon. It works fine, but bizarrely when I turn on the bathroom light, the fan light comes on for a fraction of a second. I’m pretty sure it’s wired up correctly as both the light and the fan work fine, it’s just...
  11. J

    15mm pipes with sharp right angles through a wall

    Yeah that might be my only option. It’s probably my OCD wanting to avoid making a bigger hole in the newly-plastered, freshly-painted wall, even though the skirting will hide it! Thanks
  12. J

    15mm pipes with sharp right angles through a wall

    could possibly use tectite fittings, but have never used them before and the fact they only give a 1-year guarantee doesn't fill me with confidence.
  13. J

    15mm pipes with sharp right angles through a wall

    Hi guys, looking for a bit of advice on how best to run 15mm pipe for new radiators with sharp right angles on both sides of a wall. I've just had the downstairs living room and hallway re-plastered, and chucked the old crappy rads, and ordered some nice new P+ Stelrads to go on both sides of...
  14. J

    Is this an old BT junction box?

    Having had a closer look at the top section of what I was planning to buy, there’s no external access points, so am looking at bigger enclosing boxes that just sit on top of the old junction box to hide it. This one is probably a good option as it means I can cut a suitably-sized hole into the...
  15. J

    Chasing out a tiled wall

    cheers. Funny enough it's the titan wall chaser I've got as well! :cool: I suppose worse case it doesn't work, and I'll just have to take 5-6 full tiles out.
  16. J

    Is this an old BT junction box?

    yep realized that afterwards. :-) Pretty certain its the block terminal No. 18 as you described. It just looks ancient, and also I don't like the way the cable just pops out the top of the pipe without any kind of cover over it. Have just come across this thing online...
  17. J

    Is this an old BT junction box?

    Is this an old BT junction box stuck on the front of the house? I can see a cable coming up from a pipe buried in the floor which goes into this thing, and then from that another cable (2-wire) goes somewhere under the front porch. Was tempted to rip it off the wall, as we’ve never used a...
  18. J

    Chasing out a tiled wall

    Thanks, I was just going by Triton website, so assumed 10mm was a must So should be fine just to run on 6mm. However it looks as though the cable for the shower on the new Mira needs to be on the left, but on the original Triton it’s on the right, so probably best I take the opportunity to...
  19. J

    Chasing out a tiled wall

    I was getting ready to fit a new 9.5kw shower to replace my old 7.5kw shower. We had a full house re-wire a few years back and 10mm cable was run to the bathroom so no problem there. The problem is the last leg, from the isolator pull cord to the back of the shower (approx 2m run) which I...