  1. TheFunk

    What needs upgrading to exchange a plug in oven for one over 3kW?

    Hardwired connection only Required Fuse (A): 15
  2. TheFunk

    What needs upgrading to exchange a plug in oven for one over 3kW?

    Thanks all. @ericmark & @Taylortwocities I turned off the 16amp MCB and it appears that only the oven is on that circuit. I thought the gas hob, the other plug also behind the oven, would be on it due to proximity but that's on a separate circuit. I can't provide much info on the cables. For...
  3. TheFunk

    What needs upgrading to exchange a plug in oven for one over 3kW?

    Hi, We currently have an oven installed which connects via a standard plug. Unfortunately it's on its last legs. Despite pleas to exchange to a similar wattage oven, my wife has her eyes on one that is over 3kW which I understand then has to be hard wired. I know I'll require an electrician...
  4. TheFunk

    Rapid increase in pressure during central heating

    Thanks. I was expecting I'd need to get someone in but it's helpful to know what they'd likely need to fix and how bigger job it is etc.
  5. TheFunk

    Rapid increase in pressure during central heating

    Hi, I have a Vaillant ecoTEC boiler. Over the last couple of years, I've noticed that the difference in pressure between when the heating is off, and when it's on, had been slightly increasing but it was all within normal limits. This month that difference has massively increased. Today it...
  6. TheFunk

    Drilled through 4 core lighting cable, how do I replace?

    Actually 3 of the cables are slightly smaller (no writing I can see). The other two are a similar size but the writing isn't on the cable I drilled through so perhaps there is only 1 that's actually 2.5. Thanks again.
  7. TheFunk

    Drilled through 4 core lighting cable, how do I replace?

    Thanks for all your replies. Yes it definitely says 2.5mm² on the cable. It's indented on the cable rather than printed on, so it's hard to see (and photograph) I've rubbed some pencil over it so hopefully you can just make it out in the photo. It is 1 of 5 cables in there, all the same, so...
  8. TheFunk

    Drilled through 4 core lighting cable, how do I replace?

    In the process of putting some kitchen cupboards up I drilled into some studwork and unfortunately a cable that was running through the middle of it. This tripped the downstairs lighting circuit and the main light in the lounge no longer works. I thought I'd add in a replacement section using...
  9. TheFunk

    Worktop edges with a router, what guide required?

    Hi, I need to shorten several 38mm square edge laminate worktops and apply edging strips. I understand a router is the best way to get the cleanest edge finish without chipping (cutting the worktop first and then using a router to remove the final few mm's). The only problem is I've never used...
  10. TheFunk

    Bosch Dishwasher not draining

    I checked the base tray today. It was bone dry with no obvious sign of any leaks :(. Suggestions for any other areas/components to check much appreciated? Thank you
  11. TheFunk

    Bosch Dishwasher not draining

    Thanks. The underside was the one section I didn't look at. I'll take a look but no water came out when I moved it.
  12. TheFunk

    Bosch Dishwasher not draining

    Having washed by hand for three weeks I thought I'd just try the dishwasher again and it worked perfectly for 6 washes before stopping again tonight with the same fault. Could it be that some sort of switch is being tripped? By leaving it for three weeks the water causing the issue evaporated...
  13. TheFunk

    Bosch Dishwasher not draining

    Thanks. I ran the machine with the hose in a bowl as suggested and it did pump water out once. All seemed fine and ran as it should initially. It was a 29 minute "quick" cycle. It counted down to 14 minutes normally, during which it pumped out once into the bowl, but then the timer jumped back...
  14. TheFunk

    Bosch Dishwasher not draining

    Hi, My 4 year old Bosch dishwasher has started cutting out mid washing cycle as it's not draining. I removed the waste water pump filter and there didn't appear to be anything blocking the impeller, it turned freely. I've undone the drain hose where it plugs into the drain and there was...
  15. TheFunk

    What fixings for door frame?

    Hi, I'm hoping to replace my rapidly rotting wooden front door with a composite one. What fixings would people recommend to secure the frame to the brickwork? Some have plugs, others don't and what length is better? Thank you
  16. TheFunk

    Condensate pipe frozen and leaking

    Within 20mins it quickly became apparent that a bucket just wasn't going to cut it! I'll turn the boiler off for the duration and hope the weather improves. Thanks for your help. Rather annoying that the installation means the boiler is always going to pack up when you need it most!
  17. TheFunk

    Condensate pipe frozen and leaking

    Similar to Driver123 I've just found water dripping through the ceiling. Again looks it looks like the condensate pipe has frozen (and has been for some time given how damp it is under the floorboards) and popped the seal where the white plastic pipe joins the boiler. It's a long length, 4...
  18. TheFunk

    Eurocell composite doors - are they any good?

    That is a concern. Word of mouth? I was wondering if I could fit it myself (then I'd only have myself to blame).
  19. TheFunk

    Eurocell composite doors - are they any good?

    I need to replace my backdoor. There seem to be various websites out there offering generic composite doors via identical "design your door" software. Eurocell seems to offer a branded alternative at a competitive price. I appreciate that there are better composite doors available (Solidor...