  1. ianmcd

    Replacing a Danfoss HPA2 (4 wire??) motorised valve

    just isolate the earth wire it isnt needed
  2. ianmcd

    Holes in plasterboard above boiler

    old ventillation if boiler is now room sealed just cover them up
  3. ianmcd

    New expansion vessel needed?

    Make sure you leave a drain point open while re-pressurising or no point in doing anything
  4. ianmcd

    F22 Dry error after power cut

    the problem will be with the zone valve(s)
  5. ianmcd

    Combi boiler making noise when running hot water

    well sorry but he is wrong
  6. ianmcd

    Drayton LP522 to Nest Heatlink

    yes that is correct and you will have to link out any existing thermostat
  7. ianmcd

    Combi boiler making noise when running hot water

    It isnt the heat exchanger, you need a proper gas engineer , your burner is resonating at low flame and the gas valve needs set up properly, not for a poke and go neewbie
  8. ianmcd

    Reluctance to do landlord cert

    Check his Gas Safe on the register, he may have boilers only, he will need CKR to do the hob
  9. ianmcd

    Swapped radiator now boiler won’t fire up

    unique to the Ri range of WB although i seem to remeber an ariston with similar
  10. ianmcd

    Swapped radiator now boiler won’t fire up

    At the top of the heat exchaanger there is a plastic bayonet fitting with a clear hose coming off, turn the bayonet until water comes out of the tube, be carefull the water may be extremely hot
  11. ianmcd

    Swapped radiator now boiler won’t fire up

    you have to bleed the main heat exchanger
  12. ianmcd

    HELP Header Tank not draining

    Remamber and take all the water out of the F&E tank before you cut out the blocked Tee, or you will get a little surprise
  13. ianmcd

    New boiler questions

    they will only fix the boiler
  14. ianmcd

    Gas fire help please.

    Good luck finding one of them
  15. ianmcd

    Logic Combi ESP1 35 pressure dial

    The guage capillary is blocked very common on that boiler
  16. ianmcd

    Is This Legal?

    It is a flood waiting to happen, but not illegal
  17. ianmcd

    Drayton 22mm mid-postion valve woes

    Check your HW off wire is wired in correctly, it should be wired to HW off at the programmer and satisfied at the cyl stat, these two wires connect to the grey on the mid position valve
  18. ianmcd

    Leak in pipe under boiler

    That is the condensate discharge , turn the CH off and no water will come out, break the joint clean up and remake will be fine
  19. ianmcd

    Honeywell 2 port zone valve question

    The drayton does not stop or start the pump the zone valves do