  1. flameport

    Cable size and diversity

    Then there is the question of what is meant by this mythical 'signing off' process.
  2. flameport

    What fire rated downlights are you all fitting?

    Not true, and no one cares about EPCs anyway, they are just a thing people are compelled to get when selling a house. They are also grossly inaccurate and only cover certain items that the software knows about.
  3. flameport

    What fire rated downlights are you all fitting?

    Never noticed or cared. It's a metal plate with a hole, a glass disc, a couple of springs and a GU10 lamp holder. Warranty not required.
  4. flameport

    Armoured cable sizing

    Junction boxes and other connectors are sized on the cross sectional area of the individual conductors. The diameter of the outer covering of a cable is unrelated.
  5. flameport

    What fire rated downlights are you all fitting?

    https://www.toolstation.com/integral-led-evofire-fire-rated-downlight-85mm/p58865 with whatever GU10 lamps are desired. Sealed affairs are a fail. Seen far too many from various manufacturers where they have failed after a year or two, exact replacements don't exist, manufacturers warranty...
  6. flameport

    BT phone line/service 'upgrade'

    They certainly did, as in a certain block of flats near here which has FTTP and those exact ONTs from when it was built around 7 years ago. However they have already been abandoned - the battery part still works if people can be bothered to put batteries in it, but when broadband service is...
  7. flameport

    BT phone line/service 'upgrade'

    Correct. There are no new copper PSTN services, they have been unavailable for over 2 years, the last orders for such things were in 2023. Those people that already have one and also have ADSL / VDSL or some other broadband product delivered over copper are already being migrated to VoIP...
  8. flameport

    Two 2.5mmT&E to a garage?

    An unusual choice but could still be compliant. A 32A circuit presumably? Nonsense. With thinking like that, nothing would ever be installed anywhere.
  9. flameport

    Shepherds hut electrics

    It won't be. iv - All the circuits will comply with disconnection times (if not then there are severe problems which no amount of supplementary bonding will fix) v - All the circuits have RCD protection (from the RCBOs) vi - It's a hut, extraneous parts not found unless for some inexplicable...
  10. flameport

    12V spotlight for bathroom

    Get a 230V AC one and dispose of the transformer. Vastly more selection available. 12V affairs are basically obsolete, being primarily designed for halogen lamps.
  11. flameport

    Daikin ceiling aircon unit

    Those are defrost mode, during which it will not provide any heat. If it's going into defrost mode all the time, the outdoor unit is either clogged with dirt or it's been located incorrectly, meaning it's in an area with walls on all 4 sides and a floor/surface below, which will trap cold air.
  12. flameport

    Installing single gang in double knockout box

    Yes, assuming the device to be attached has the fixings offset to the left side like that.
  13. flameport

    TN-C-S or TN-S

    C and D are both variations of TN. If someone really wanted an inverter or generator installation to be TT it would look like this but no real installation will be like that. Inverter / generator installs are almost always TN-S, with the N-E link internal to the generator or immediately...
  14. flameport

    Advice on chasing leads into solid wall for TV

    BS7671 says otherwise. 110.1.2(vi)
  15. flameport

    Installing single gang in double knockout box

    It's this: Drill 2 holes 42mm apart in the back of the existing box, fix bracket with screws/plugs. Careful measurement required to ensure bracket is level and centered both vertically and horizontally.
  16. flameport

    Double oven- what would be the best flex outlet/switch options

    Exactly. It's the standard arrangement used in domestic kitchens everywhere for ever. 'Advice' from kitchen designers and vendors should be ignored.
  17. flameport

    Comando Socket for EV charging (In Scotland)

    A 'granny lead' in the UK and most other countries refers to a cable with an AC plug on one end, a control box and a vehicle connector at the other. For the UK typically a 13A plug as shown, but can be other types such as the blue 16A or 32A versions. Other countries use plugs appropriate to...
  18. flameport

    Energy saving, advertising rubbish or what?

    That email is just a 'feature' so that people believe that connecting their thermostats to remote servers for spyware purposes is beneficial to them. It's totally meaningless.
  19. flameport

    Double oven- what would be the best flex outlet/switch options

    Oven / cooker outlets should be flush mounted. If surface, then you are unlikely to have enough space to fit the appliance in front of it. They all need a 35mm or deeper box due to the size of wiring used with them. Why? They will be switched off only for cleaning or maintenance. Neither of...
  20. flameport

    TN-C-S or TN-S

    That contains some elements of truth but like many things that can be 'read online somewhere' it's also full of fails. If a TN-C-S supply is used for some outbuilding, AND that outbuilding also has extraneous conductive parts such as a metal water pipe, then those parts require bonding to the...