    New Roof - Cause For Concern ?

    Are the spots anywhere near the above ridge ? Centre line
  2. D

    Roof help!

    The tiles will read a different pitch to the roof .. Ppretty logical really . And irrelevant. The rafter pitch is what you should be interested in . Putting different batten size won't help . Post above is correct if I understand your post.
  3. D

    New slate choice for old slate roof

    I've seen cement fibre slates fail in 12 years . There is the Glendyne alternative to Welsh and more economical . There are some decent Spanish too , as long as they are t1 s1,w1 then should be trouble free. Something like a cipa h12 are good and you can get a dite specific guarantee for up...
  4. D

    Chimney back gutter issue

    You have what appears to be the original back gutter and a newer apron . The back gutter should have been replaced looking at the state of it and definitely one piece
  5. D

    Sandtoft 20/20 tiles around Velux Windows 15 Degrees

    It's a poor example . Cut course under the window for one ..
  6. D

    Lead flashing to hip

    As above leads too narrow and badly fitted . It could have had hip tiles bedded as per ridge . I'd be inclined to remove the lead and put a hip tile on. Asbestos slate btw
  7. D

    Leaking Valley

    The lead should have been fully supported . An open valley used . What you see here we've seen many times on preformed grp "dry" valleys . Fitted by others as we don't use them. The sandtoft 2020 is a good tile
  8. D

    Velux window install

    He's asking about flashings and wether they are weather tight . Which they are
  9. D

    Velux window install

    They would need to move the whole window down a couple of inches , or up 8 approx. It's not going to leak
  10. D

    Roof Repairs

    It can be felted. Probably cheaper than lead with its adaptions . Thr felt shouldn't be laid on top of the lead .
  11. D

    Leaking concrete tile roof

    Fwiw the hips are not properly pointed at the but joints .
  12. D

    What is this capping on side of roof tiles and is it an issue that it's coming away?

    The problem here is the verge was bedded the pointed in two different mortars . The verge should be pointed in the same mortar used to bed it . Done correctly it will outlive any dry verge
  13. D

    Rain pouring off dry verge

    Roof pictures
  14. D

    Fibreglass roof bond

    As above two tiles slipped leaving no head lap is a leak. Also the mortar that has been jammed here and there can dam water and cause a leak. Imo grp is for boats . To get the correct fall you'll need to adjust the gutter soles . You be better off getting a good felt flat roofer in the torch on...
  15. D

    Missing mortar in chimney perps

    Looking closer , the weep hole still has a bit of the brickwork bed blocking it . This can cause a dam effect and any build up of water could drip over the inside tray turn up . If it's low
  16. D

    Tile vent identification

    Looks like a Redland plain tile . The vent looks like an aftermarket vent . Could one of a few
  17. D

    Damp in ceiling of dormer - Conflicting advice

    Fluff sandwiched between plasterboard and felt . Isn't correct . You should have at least a 50 mm air flow gap between the felt and insulation . Soffit or ofv should be there and some form of venting at high level depending on roof design . Curious as to which Marley tile is no longer made . Do...