  1. T

    shower pump switching

    why not fit one of these instead? http://www.mirashowers.com/magnaflash/magna.htm
  2. T

    Boiler in a cupboard in a bathroom

    The argument/point i am trying to make is that the boiler is definately not allowed to be fitted in zone 1/2 (601-08-01). But the op was going to fit it within the confines of a secured cupboard (you could read that as small room) in zone 2 now imho theres a world of difference between that...
  3. T

    Boiler in a cupboard in a bathroom

    But the regs contradict the blurb in the nic connections mag,how on earth does a bath panel with two screws in it limit the extent of zone 1.
  4. T

    Are Heat Shields a MUST?

    If it was removed from underneath the catalytic convertor i would replace it because they become extremely hot and if you park over combustable material i.e grass, waste paper the inevitable will happen.
  5. T

    Is my lighting circuit legal??

    Perfectly acceptable happening more and more with the use of downlights :evil:
  6. T

    Rover 216 GTi Keeps staling

    Coil or ignition amplifier/module.
  7. T

    Boiler in a cupboard in a bathroom

    It doesn't change zones,its outside zones if accessible only with the use of a tool. So surely if the door is secured/screwed regs have been met.
  8. T

    Boiler in a cupboard in a bathroom

    Pensdown if what you are saying is true i have seen the regs breached hundreds of times i.e airing cupboards within zone 2. Which issue of the Nic rag was it in?
  9. T

    Boiler in a cupboard in a bathroom

    Well it needs to be easy to get to should the customer want to turn the system off. The FCU could be next to the controller / programmer to allow the customer to have easy access to it. Then for the SAFETY of anyone working on the boiler it is a good idea to fit an additional ISOLATOR...
  10. T

    Boiler in a cupboard in a bathroom

    Chris i've looked at a few boiler manufacturers of those they all say the appliance can only be fitted to zone 3, as IP rating of boilers is generally IP20.Therefore if housed in a cupboard within zone 2 it effectively becomes zone 3 so imho perfectly acceptable.
  11. T

    My car eats headlamp bulbs!

    Oh really silly me there i was thinking that all loads on parallel circuits receive the full circuit voltage. Do tell where the extra voltage comes from on a 12 volt regulated supply.
  12. T

    Vauxhall Vivaro 1.9TD cutting out fault

    Sounds like mass air flow sensor.
  13. T

    sticking clutch/?

    Sounds like you've got a cooling system fault and possibly clutch on its way,was it definately slipping i.e engine revs rising car going nowhere?
  14. T

    My car eats headlamp bulbs!

    :roll: You have got to be kidding! Just a thought clazza when your fitting new bulbs are they clean i.e no traces of grease on bulb glass from dirty fingers. Failing that get the output of the alternator checked properly preferably by an auto electrician one that knows the difference between...
  15. T

    Warmup Underfloor Heating Connection

    why don't you forgo the socket in the loft and replace it with one of these http://www.screwfix.com/app/sfd/cat/pro.jsp?cId=A231858&ts=34145&id=14770 steve
  16. T

    valliant eco plus

    Had same fault recently on a vaillant ecomax, thanks to advise from ChrisR and others fitted new diverter and all is well. :) Steve
  17. T

    Trevi Boost Ventura Shower - Has anyone got one

    T'd off riser between hw cylinder and vent pipe never been a problem.
  18. T

    Valiant Eco tec condensing boiler Airlock??

    You hav'nt inadvertantly turned the cold water service valve off have you? Steve
  19. T

    Trevi Boost Ventura Shower - Has anyone got one

    I've got one, never had a problem good performance too. Steve
  20. T

    When does a house need re-wiring ?

    FFS if you know your electrics are fine why post!