  1. T1GERIII

    ew002lcdg-2 eurosec alarm can't set low batt fuse

    Post picture of the main panel inside the house
  2. T1GERIII

    Trying to disconnect zone from Paragon Super II

    Correct, that is the fuse carrier for the panel
  3. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Engineer code > zone number ( I.e 02) > yes/enter > 00 Not used > enter > back to installer mode > 99 enter escape installer mode
  4. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Remove zone wiring and power to the sensor from aux 12v and 0v. Enter installer mode and disable zone in programming.
  5. T1GERIII

    Pyronix Euro46 Zone setting

    Level set - If ‘Yes’, the system becomes ‘level set’ (having one area set only at any one time). If ‘No’: The system becomes an ‘area’ system (fully independent areas).
  6. T1GERIII

    Pyronix Euro 46 v10

    private messaged
  7. T1GERIII

    Scantronic 9751 rewiring, house refurb

    I’d guess your top 3 cores then the lone 12v + and -. Best bet would be to trace the O/P cores I labelled as bell that will lead you to the others for certain.
  8. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Bell will only sound for 15-20mins if the battery inside it is still healthy once the power to it is removed
  9. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Ignore the bell. Remove the zone cabling to the pirs you wish to re-route Remove the 12v 0v feed for them Re-route and put back as they were Exit engineers mode
  10. T1GERIII

    CCTV networking

    TP Link power line adaptor
  11. T1GERIII

    CCTV manufacturers with user manuals ?

    The end user would receive an instructed handover from the installer on the use of the system and application chosen it’s not a one app fits all so manufacturers can’t provide you with that
  12. T1GERIII

    Pyronix Euro 46 v10

    Private messaged you
  13. T1GERIII

    No fused spur

    YeeHawwwww!
  14. T1GERIII

    CCTV manufacturers with user manuals ?

    Hikvision website has all user manuals pdf and firmwares if required https://www.hikvision.com/uk/products/
  15. T1GERIII

    How to connect manual call point on alarm panel

    What alarm panel is it? These MCPs are 24v operation
  16. T1GERIII

    Routing Cat6 cable CCTV

    Forgoing the conduit will save time just clip the cable round if you use the back entry on the junction boxes you can use the mortar line to take the cable into it
  17. T1GERIII

    Scantonix 9651 System Disabling

    They have a row of dip switches on the back 1-4 I believe on those so if you have more than one keypad you address them as such.
  18. T1GERIII

    Scantonix 9651 System Disabling

    No need to down power, remove the old keypad replace for new make sure they are addressed the same. Just avoid shorting the +12v and negative You will get an internal tamper alarm on removing the old keypad but you could just wire up the new keypad then enter engineers menu before continuing...
  19. T1GERIII

    Pythonic enforcer v10 works supervn f1 fault

    low battery in the wireless bell.
  20. T1GERIII

    Scantonix 9651 System Disabling

    The 9943en will work with the Scantronic 9651 panel