Search results

  1. J

    4K resolution HD Televisions???

    Anyone had any experience with the new 4K resolution HD tv's, are standard HDMI cables suitable for them? Or do they require a specialist cable? Thanks
  2. J

    Boiler Flue?

    Hi, my friend is looking to put a boiler in a ground floor Utility and would like the flue to come out of the roof to avoid nuisance plume into the garden and car store. I assume the flue could run up through the floor above (boxed in) and out of the roof, provided that the boxing is accessible...
  3. J

    Thermal Store V Unvented Cylinder

    What are the benefits of a thermal store versus an unvented cylinder i.e. Megaflo. I am sorry if there have been threads on this before but most of them don't really contain the answers! Thanks
  4. J

    Hot water question

    Hi, Will 2 x 300ltr Megaflos or ACV's cope with a 5 Bed B&B with 5 separate en-suites and large kitchen? Any advice will be appreciated
  5. J

    Pipe insulation???

    Hi, Does anyone know which pipe insulation offers the best thermal resistance. Foil wrapped mineral wool insulation or Armaflex foam type insulation? Many thanks
  6. J

    Hot and Cold Pipework question

    I need to get a hot and cold supply across a room which has no ceiling space available. Only thing is the room is going to have underfloor heating. I would like to run the hot and colds within the floor before the screed is laid but would like to avoid excessive heat transfer getting to the...
  7. J

    UFH/H&C pipework question

    Hi, I need to get a hot and cold supply across a room which has no ceiling space available. Only thing is the room is going to have underfloor heating. I would like to run the hot and colds within the floor before the screed is laid but would like to avoid excessive heat transfer getting to...
  8. J

    Repainting cellar floor ??????

    Hi, I'm looking to repaint a cellar floor - I painted it some time ago and unfortunately there was a mini flood down there (about 1 inch of water). The paint has all bubbled and is flaking off now. Is there a 'non-soluble' type of hard wearing floor paint available so if water does get in...
  9. J

    Recessed smoke detectors?

    Hi All, Does anybody know whether you can buy recessed smoke and heat detectors? i.e. so they are hidden away flush with the ceiling. I am obviously aware they don't want to be 'hidden' to such an extent where this has a detrimental effect on it's operation, but wondered if any were...
  10. J

    Protecting Pipes under floor??

    Hi, I am extending a radiator circuit across to a new radiator. The only route to it is to run the new copper flow and returns beneath the existing floor. The floor is simply exiting flags laid on the earth. I would like to obviously insulate them and protect them. It is a very old property...
  11. J

    Which oil-fired condensing boiler?

    Does anyone know of a good 80kW oil fired condensing boiler? I know Worcester Bosh do a 50-70kW, not sure if they do an 80kW version?
  12. J

    Fire rated cable?

    Is Low Smoke Zero Halogen (LSZH) single insulated cables to BS7211 a fire rated cable? Or is this considered as an insulated fire cable?
  13. J

    Gas Pipe in screeded floor

    What are the current Gas Safe regulations for installing copper gas pipework beneath the screed? Is there just a requirement to wrap in protective Denso tape. Are joints or connections an issue under the screeded floor? Are there different regulations if the screed also contains underfloor...
  14. J

    Cabling routes/joints??

    Could anyone please advise what the current IEE / Part P regs are when installing cabling beneath suspended timber floors i.e. in the floor of a bungalow. Should they be neatly clipped to the side of the joist. What happens if a joint is needed in the cabling, is the standard method of...
  15. J

    Pipe insulation??

    Hi, What (if any) are the advantages of foil backed pipe insulation as opposed to standard black pipe insulation.
  16. J

    Frost Protection?

    Could someone explain how the 'anti-frost' mode works on Vaillant boilers? Does this activate the boiler / heating system if the temperature drops below X deg C? Thanks
  17. J

    Upgrading from single-phase to two-phase?

    How easy is it for the utility company to convert from a single-phase electricity supply to a 2-phase supply. What is involved? Apparently this may be more cost effective than a new 3-phase supply. It is a large house that may require more than a single-phase supply can cope with. However...
  18. J

    Gas supply

    Can you build an extension over an existing gas pipe. The pipe is after the meter, i.e. presumably not the responsibility of the gas supplier. Is there a Corgi regulation on this?
  19. J

    Ground Source heat pump

    Has anyone had any experience with installing a domestic hot water circulation loop to a domestic hot water cylinder being fed by a ground source heat pump? The new house really needs to have a continuous HW loop as some draw offs are over 20m away from the plant room. As you all know, on a...
  20. J

    Underfloor heating

    I wonder if someone could help me please, I am considering underfloor heating but there are some timber floor finishes going on top which may be quite thick. The underfloor heating manufacturer say a maximum of 32mm timber floor finish should be installed. What are the ramifications if this is...
Back
Top