  1. shambolic

    chronic air in radiators and concurrent boiler pressure rise - combi

    Still needs flushed again to remove corrosion. To get it all out 100% is a time consuming job. Depends on pipe runs etc if drop feed then each leg needs drained to endure all crap out. You may never get it all out.
  2. shambolic

    HELP, cannot remove my Idweal Isar diverter valve head

    Gonnae end in tears. Or electrocution or flood. Or both!
  3. shambolic

    Heat only Vs System boiler Vs Combi (running costs)

    Tbh you’d need to research your own application as mine was specifically designed for my own house when building it. the spec is now 5/6 years old and things have came on and got better even from then. But basically 3 zone system one of them being hot water. Other 2 zones are rads and then 12...
  4. shambolic

    Nearly done

    First proposal. Might be a bit big tbh. :eek:
  5. shambolic

    Nearly done

    Wife’s a director of a bank. ;)
  6. shambolic

    Nearly done

    Finished. Wife now wants and extension and garden room :rolleyes:
  7. shambolic

    Ideal Classic FF250 issues

    Ps the neutral point is where the cold feed from F&E tank joins into system. Usually on a 22-15 tee at the cylinder return. Run a magnet over the copper pipe. If it sticks or is attracted to pipe then it’s full of sludge(iron magnetite) as magnet shouldn’t stick to copper.
  8. shambolic

    Ideal Classic FF250 issues

    Get a better engineer. You either have a intermittent sticking pump. or you have a blockage in the cold feed at the neutral point on your system or a blockage elsewhere.
  9. shambolic

    22m Gas Supply

    As said above it’s not the Size of the pipe it’s the dynamic working gas pressure at inlet with boiler on max and other gas appliances on. you are allowed a 1mbar drop over pipe run from meter dynamic pressure. So if meter is 19mbar with appliances on then you are allowed 18mbar at boiler...
  10. shambolic

    Heat only Vs System boiler Vs Combi (running costs)

    I have a SS combi running an unvented cylinder with draw offs to all hot taps apart from my en suite which comes off the combi for the constant 20l/min shower. the heating is under floor with oversized rads upstairs to run at 55deg. Has outside weather comp and opentherm internal controls. Hw...
  11. shambolic

    Have I been Conned ?

    Yes really, it has been opened up to others but mostly sold in Scotland by Mr Central Heating. It’s called the combi exclusive when sold through most other outlets.
  12. shambolic

    Have I been Conned ?

    You in Scotland? Would love to know the fitter but probably against page rules putting up his company name.
  13. shambolic

    Have I been Conned ?

    It’s built for MR central heating as it’s the cheap base combi
  14. shambolic

    Have I been Conned ?

    That’s the bit that says 24kw on it
  15. shambolic

    Have I been Conned ?

    Jesus that prv is rough and should have a compression fitting not soldered.
  16. shambolic

    Have I been Conned ?

    Flap is missing :LOL: Wonder why:whistle:
  17. shambolic

    Have I been Conned ?

    They are all 24kw to heat. It’s the hot water delivery that changed with higher outputs not the heating. Couldn’t tell you warranty but only 12yr warranty is for vogue max by accredited installer
  18. shambolic

    Logic Boiler intermittent F1 fault

    Or water dripping onto switch from flue
  19. shambolic

    British Gas HomeCare refusing to fix boiler unless customer agrees to PowerFlush

    L3 is no flow thermistor fault. This could be pump, plate hex or main hex. L5 is return thermistor fault. But could be due to engineer disconnecting stat at some point as boiler stores fault codes. if they fitted and maintained it from new (and you haven’t drained rads for decorating etc) then...
  20. shambolic

    Tado Extension and Ideal Independent Combi 35

    What readings did you get on your FGA and gas rate after putting boiler back together?