Search results

  1. M

    floor stander potterton flow switch?

    been out to a potterton pro floorstanding condensing boiler only a couple of years old but they had it moved only a few feet and it hasnt worked since now i went and im just back from there and i said "if its just been moved 3 feet and nothing else then check to see if hes crossed the pipework"...
  2. M

    Saunier duval good or bad?

    I would like your views on Saunier Duval boilers please. I am asking as i have been fitting these for the past 2 years as a cheaper option than the worcester 28i juniors which i find very expensive now as the price went mad when it went from a normal 28 i junior to the condensing model. I have...
  3. M

    glowworm compact no heat

    Hello,im wondering if any of you have come across a fault on a glowworm compact 80 e were the hot water is ok and when you ask for heating it fires for 30 secs then cuts out and will fire up again after a couple of mins.It seems like no circulation as the flow is red hot ,the pump is working...
  4. M

    back boiler no heat and banging

    Just been out to a back boiler which has gravity circs and the hot water is ok with the heating on but the rads dont get hot and if they turn the heating off for h/water only it starts clanking and banging now the pump is newly fitted by the customer and its all vented,water in the tank so what...
  5. M

    will wilo gold fit wilo pump off a s/duval enviro

    will a wilo gold fit into a body of a wilo pump from a saunier duval enviro plus boiler it
  6. M

    no circulation help

    Hello im just wondering if you can help im a bit stuck ive been out to a power flush and i had warned that it may not work so i went done the flush and still the same proplem which is "the system is a conventianl boiler, back boiler the customer rang me on sunday he fitted a new pump but the...
  7. M

    Worcester 24i strange fault

    I need some advice on a worcester 24 i fault please lads. It is standard 24i now what happens is for c/h and h/water it goes through its sequence it starts to spark and then it dosent ignite,now i was thinking gas valve but if i blow down the aps tube it starts to spark then fires up every time...
  8. M

    Old pipework failed, whos fault ?

    Im in my first yr as my own boss and for just over a year i had no proplems tht werent easy to sort out. I done a boiler change old floor standing to combi system i also fitted towel rail rad,new trv's and powerflushed it. I had to use the old circs as hot and cold supplys to combi,they...
Back
Top