Search results

  1. vera121

    Recessed spot vs RSJ

    I found another 2, also cutting of joists.
  2. vera121

    Recessed spot vs RSJ

    Those pesky RSJ's getting in the way of the down lighting.
  3. vera121

    Outside lighting, don't bother with the cpc,

    I’m redoing it next week including new 3 core swa as some of the cable is taped over, damaged and some of the terminations have let water and the armouring has gone rusty. It’s already supplied from a 30ma rcd. probably use galv conduit boxes.
  4. vera121

    Outside lighting, don't bother with the cpc,

    3 more whiska boxes, 4 in total, all the same.
  5. vera121

    Outside lighting, don't bother with the cpc,

    4 off, 2 core swa terminated in Wiska boxes suppling LED pir lights, earth continuity - no!
  6. vera121

    Is It Wrong???

    I like a drop of Laphroaig.
  7. vera121

    Controversy regarding LGBT lessons in primary schools

    This is why relationship education is needed in younger children, search; Riley Hadley a 12 year old boy who took his own life. Even The Daily Mail mentions homophobic bullying, but the moronic Sun leaves out the homophobic bullying aspect, I presume the Sun wouldn't want to upset its tit...
  8. vera121

    ECIR photo's

    Doing and ECIR today and the cpc's are being used for the two way switching!
  9. vera121

    11 Weeks Ago

    I landed at Heathrow form Bangkok on Friday evening. While in Thailand we were temperature checked at the hotel, entrance to the airport, at the boarding gate and on the plane before take off. (A couple of people were turned away at the boarding gate, as their temperature was too high). Hand...
  10. vera121

    Quality PAT testing.

    perhaps it's me been picky, I would have thought it would have been safer to change the plugtop also the tester would have to had the top off the plug to check the fuse size so quite easy to replace.
  11. vera121

    Quality PAT testing.

    BS 7671 is for fixed wiring. This is about portable appliance testing and some half wit who's been on a 'course' and deems this plugtop acceptable.
  12. vera121

    Quality PAT testing.

    Passed!
  13. vera121

    Controversy regarding LGBT lessons in primary schools

    These lessons are to inform the children that not all relationships are ‘mommy and daddy’ they are not teaching them the physical aspect of any relationships. The situation in Birmingham has got out of hand, with daily protests, intimidation, the school closing early, death threats and court...
  14. vera121

    Jeremy Kyle show death

    Jeremy Kyle show, sponsored by Sun bingo, well suited.
  15. vera121

    Replacement parts - guarantee?

    Kenwood CK405 main oven selector switch. I had a new switch from espares in April 2017, this switch failed Jan 2018 and they replaced it foc. The switch has failed again Dec 2018 and they are refusing to replace this time round. The are stating as I ordered it April 2017 it is now out of...
  16. vera121

    Vicar supports May's Brexit, hooray!

    I watched Monday's Newsnight debate, I think she's very lonely woman, nasty piece of work. Were they actors or supposedly members of the public?
  17. vera121

    Enough down lighters?

    Whilst nosing on Rightmove, a little over the top with the spots?
  18. vera121

    'The builder did the electrics'

    Customer "Lights in the new (3 years old) kitchen not working properly and coming on dim etc" I have a look and straight away it a missing neutral. After taking a few spots down I find this. No need for those pesky cpc's or JB's and all the spots are class 1 fiitings.
  19. vera121

    British have had enough

    This makes me proud to be British. This doesn't.
  20. vera121

    False ceilings.

    Photo speaks for itself!
Back
Top