Search results

  1. C

    UPVC foil / veneer peeling bubbling

    I know this was asked in 2010, but wondered if there is any solution, can’t afford to replace my double glazing, even though it’s 19 years old. The window frames have the veneer peeling at some of the ends, wonder if contact adhesive would be the solution, also not sure how to flatten the veneer...
  2. C

    Need replace under sink waste pipes

    Hello The piping under my sink is B&Q and almost 20years old, it’s never been very successful, keeps popping apart, which is why there is a cable tie holding it together. I can provide measurements if it would help the main reason originally was to get two appliance connections, but these...
  3. C

    Is Adjustment of fence posts ok

    I bought 3’ fence panels and concrete posts, my son intended doing this but now can’t, just got a builder in to do it, and realised as I am having 6” gravel boards, with 3’ panels, the posts aren’t tall enough. He has proposed removing the ‘noggins’ from the posts, to allow the posts to sit 6”...
  4. C

    Insulating of boiler return pipe work

    Just had a new boiler fitted, my only concern is that the boiler inlet pipe work is not insulated, it is too hot to touch, therefore I would have thought exposed pipework of this temperature should be insulated for safety reasons. But also not insulating this pipework will result in at least a...
  5. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Hello looking at the possibility of having a Worcester Bosch Greenstar 15Ri installed, found a company offering to supply and install for £2060, plus may get an extra £100 off, they are No1 on trustpilot. Also interest free for 2 years. Offering a 10 years parts and labour guarantee, need to...
  6. C

    Grundfoss UPS 3 settings

    I installed a DAB Evosta 3 exactly a year ago yesterday, all ok until yesterday, when the boiler continued to cut out on over temperature, lots of banging and crashing. My heating engineer tried lots of things but made no difference, eventually I decided to swop the pump, installed a grundfoss...
  7. C

    How to fit a room stat to a system that’s never had one

    Need to know How to fit a room stat to a system that’s never had one my daughter has a very old house, she has a vented system, but no room stat, has to keep opening shutting radiators some advice please, also without wiring if possible Thanks
  8. C

    Shower intermittent flow problem

    Need a section on here that covers showers..... have a Milano Elizabeth shower mixer, often when I open the flow valve fully there is no flow at all, it is fully pumped, but a flow is possible without the pump on, if I move the temperature control slightly back and forth the flow returns...
  9. C

    Alpha 28x error code E37

    I have a Alpha entec 28x with an E37 fault code, but is intermittent, would this mean that it could be something other than a transformer PCB replacement ? Also can an electrician or other competent person replace this ? Or would it need a gas safe person ? thanks
  10. C

    LP 722 Programmer modification

    Hello I have an LP 722 programmer......unfortunately my heating system has a problem......the boiler doesn’t like it when heating hot water only..had great difficulty controlling the temperature, often cuts out iron over temperature, maybe it’s a piping configuration issue, I don't know. But my...
  11. C

    problem with CH makeup tank getting hot

    I believe mycentral heating was fine before I had my extension built, it is a fuly pumped system with ahot water cylinder etc. During the extension I have had several rooms added and the rads have about doubled, using same boiler ( potterton neataheat ) and pump. When the CH pump is on low...