  1. C

    Twin brown and earth - can one core be marked blue for neutral?

    I'm currently building an extension (done under building regs including the electrical) and I've inadvertently run a couple of twin and earth cables each with two brown cores. One to an extractor fan and one to an outside socket. I've no idea where this drum came from as I've never knowingly...
  2. C

    Greenstar 25i erp pressure gauge

    Very simple question regarding the water pressure gauge on a Greenstar i25 erp boiler. I went to view a property for sale today and noticed that the pressure gauge was showing 0. The boiler itself was working (heating and hot water) but can someone please confirm my thoughts which are that the...
  3. C

    Mixer tap screw handle removal

    I need to replace the cartridge on a mixer tap but need to unscrew the small metal cap at the top of the handle to get to the grub screw. The cap won't move under hand pressure and there is very little metal to grip so does anyone have a trick to removing these without breaking the ceramic?
  4. C

    Meter Tail Clamps

    Really simple question this one! I'm installing a new consumer unit (under building control) and need a couple of clamps for the tails but can't seem to find them anywhere (looked on eBay, Toolstation, CEF, TLC.). Can someone please point me in the right direction as I would think these must be...
  5. C

    32mm incoming mains supply - reduce to 22mm or 15mm

    I have a new 32mm incoming water supply which terminates directly below where my new boiler will be located. My thoughts are that I should reduce from 32mm down to 22mm and then where I tee off for the boiler, I use a reducing tee to provide a 15mm feed for the boiler and another 15mm feed for...
  6. C

    GoSystem QP8088H Auto Power or QP8937H Auto Swirl?

    I've decided to buy myself a new torch and need it for both general plumbing work (I am not a plumber but am refurbishing a house and do my own pipework) and I have just got into the world of stationary engines so I want to be able to undertake brazing work on those. I think the GoSystem QP8088H...
  7. C

    Light Fitting Resonance!

    I have a light fitting (photo below) which is making a very low volume "buzzing" sound even when the lights are off. This changes slightly in pitch and volume when the lights are turned on. Really not sure what is going on as there are no electronics involved so I think it must be some form of...
  8. C

    Combi system losing pressure

    I have a combi system (Baxi 224) in a rented 1st floor maisonette that is losing pressure and by losing I mean dropping to 0 overnight. I first had a problem three weeks ago but assumed that it just needed topping up (was low but not 0). Yesterday the system failed ( 0 pressure) so I filed and...
  9. C

    Cast iron radiator - how to ensure the valve body is tight

    A very simple question to answer by someone in the know but anyway here goes!. I have a cast iron radiator with valve bodies that screw directly into the radiator. I applied what I thought was copious amounts of PTFE tape to the valve thread (10 turns) but when the valve is screwed in and...
  10. C

    Roof insulation with plasterboard backing - benefits against cost

    I'm in the process of constructing a kitchen extension with a pitched roof. Plan (signed off in building regs) is to use Kingspan K7 (or equivalent) between and over the rafters with a 12.5mm plasterboard finish. Insulation with a plasterboard backing seems to be a lot more expensive than buying...
  11. C

    Eves tile requirement for Marley Modern interlocked tiles

    Simple question. I think the answer is no but could someone please confirm if I still need to use eves tiles with interlocked tiles (Marley Modern or similar). Thanks
  12. C

    DIY Moling for new water main feed

    I need to run in a new water main feed necessitating moling under an existing passageway. I intend to dig the required holes at either end myself but still I am being quoted around £1000 to undertake the moling. I am aware of existing services (gas feed just below the surface) and my thoughts...
  13. C

    Cocrete lintel resting on top of another lintel

    I am constructing a kitchen extension and building a new utility room and together they will form an "L" shape around the existing kitchen. The roof (which will be pitched) will be at different heights for the kitchen and utility structures so where the roofs meet, there will be a change in...
  14. C

    Waterproofing an external brick wall built below garden level

    I am in the process of constructing an extension and would like some advice please on how to waterproof part of the external wall which will be below the level of the adjacent garden. To clarify, the garden slopes upwards away from the house and I have dug out to allow for footings etc. and am...
  15. C

    Advice On Setting Up To Undertake Landlords EICR

    Not an electrical problem as such but more a request for advice on a potential career! I am a qualified electrical engineer (so not an electrician) but I am very practical and undertake my own electrical work (house re-wire, panel change etc - with professional sign-off by others where required)...
  16. C

    Appliance Waste Fed Directly Into Soil Pipe Below Floor Level

    I am in the process of building a new utility room and am looking to minimise the drainage requirements for a dishwasher, sink and washing machine. The utility room will be adjacent to an existing outside toilet (to be retained) and I noticed today that the sink next to this toilet drains...
  17. C

    New consumer unit RCD tripping

    I have changed out an old fuse box for a split consumer unit (will be notified to local authority). On one side I have sockets, cooker etc. and on the other, lighting, boiler etc. The left hand side (RCD1) works fine and on the right (RCD2), there are no problems if just the lighting circuit is...
  18. C

    How to work out the size of tap connectors

    This is a daft question I know but I have a tap (European) with connectors and I am struggling to work out what size the connectors are. Ideally I want to convert so that that I can connect to my 15mm isolator valves the ends of which are too large for the tap connectors. The internal diameter...
  19. C

    Magnetic sludge remover - are they all the same?

    I am installing a small (4 rad) combi boiler heating system and am after some guidance on what make/model of sludge remover is best to use or are they all really pretty much the same with the cheaper ones performing just as well as the more expensive ones or are the more expensive ones worth the...
  20. C

    Monobloc tap - requires tap connectors smaller than 8mm

    I bought a display tap (no tap connectors) a few years back from Bathstore when they went bust. I'm now looking to use the tap but the thread for the tap connectors appears to be smaller than the smallest tap connectors that I can find (8mm). I believe it requires 6mm tap connectors which as I...