Search results

  1. S

    Built in NEFF Microwave gone faulty. Worth repairing?

    I have an approximately 6 year old NEFF 1000W microwave that has gone faulty. symptoms - LED display is working ok. On all power settings, microwave turntable & fan start but I cant hear the magnetron firing up. After about 20 seconds, Microwave stops. No beeps, no error codes. Just stops...
  2. S

    Built in NEFF Microwave gone faulty. Worth repairing?

    I have an approximately 6 year old NEFF 1000W microwave that has gone faulty. symptoms - LED display is working ok. On all power settings, microwave turntable & fan start but I cant hear the magnetron firing up. After about 20 seconds, Microwave stops. No beeps, no error codes. Just stops...
  3. S

    Tecumseh refridgerator compressor start device availability

    Hi folks, I have a Tecumseh compressor (Type THB 1330 MKS) on a Hotpoint larder fridge. The start device is totally burnt out. Fell apart in my hands. :cry: The compressor windings all test ok, approximately 78 Ohms between pins, Infinite resistance to earth. So the motor seems ok. I...
  4. S

    6A RCD random operation. No obvious root cause.

    Wylex 6A MCB/RCD fitted as part of a Part P installation. Working fine for two years. The upstairs lighting circuit is via a radial layout, not loop-in. For past four days the RCD has been tripping out at random times during night hours. Frequently after all lights on the circuit have been...
  5. S

    Built in NEFF Dishwasher model S5456X1GB/12 not heating wate

    My Neff's gone Naff! :cry: First indication of there being anything wrong was that the short 30 minute program was still running after 90 minutes, and the time left to program end was incrementing, not decreasing. On further inspection and test I discovered that the wash water is remaining...
  6. S

    AEG-Electrolux - L14850 Washer/Drier. Cold water inlet Q.

    Have just purchased above m/c, due for delivery next week. I understand from the retailer that the cold water feed needs to have a vertical connection due to the overfill protection device supplied with machine. My existing inlet is currently horizontal and close to mains sockets (Under...
  7. S

    Hotpoint RLA31 larder fridge not cooling.

    Hi, I have a Hotpoint RLA fridge. Stopped working during the summer. Changed thermostat but fault remains. Confirmed operation of new thermostat with voltmeter. Could therefore be motor. How much for a new motor?, could I change it without disturbing the compressor? Any thing else that could be...
  8. S

    Advise on latest external sounders/bell boxes.

    Time to change the old bell box! (Menvier TS690 system) I am considering the Honeywell 8EP420 Respon8 or Aztech 2000 unit. Are there any known issues with these boxes or is there better on the market?
  9. S

    Menvier TS690 alarm system. No external bell

    Hi Folks. I have breathed life into my Menvier TS690 alarm system. Walk test shows all circuits active and Bell test proves external sounder/strobe active. However, when I activate the alarm the external strobe flashes but there is nowt from the sounder. I set the sounder delay to 15 seconds...
  10. S

    Where can I resource spare parts for a Menvier TS690 alarm

    Any thoughts as to where non-trade can purchase spare parts for a mature Menvier intruder alarm system. In particular I am trying to resource a control panel for a Menvier TS690. The existing panel has stopped talking to the system controller and the LCD panel has lost clarity. If parts are...
  11. S

    How do I clear TS690 Fault Code C.TMP 01?

    Old alarm system, came with house. This morning as we left property we tried to set alarm as normal, but system would not recognize our normal pass code. Wife tried several times to no avail. I then tried entering "1111"This is NOT our pass code but I was desperate to see if panel was...
Back
Top