  1. B

    TRV

    I changed a TRV on one of radiators two weeks ago as the old was broken. (I tried to release with a screwdriver and also removed the whole pin but the hot water still wasn’t being released through) The pipe around the valve was very hot so it was clearly this. I then replaced the old TRV...
  2. B

    Potterton Suprima 60 HE Ignition Problem

    I am experiencing a problem with my Potterton Suprima 60 HE. The boiler won’t seem to ‘kick in’ and fire up. The boiler isn’t in lockout ever ie red light on The time programme is also working fine. It looks normal in terms of the electrical side. I have taken out the pcb and gave it...
  3. B

    Bathroom Ventilation / Mould / Dampness

    I live in a semi detached bungalow and have a problem with my bathroom ventilation. After showering or having a bath the tiles are so wet I spend 20minutes plus drying down all the tiles. The whole bathroom is tiled with a plastered ceiling, with a small radiator. I have a 6” ceiling fan...
  4. B

    TRV Sticking constantly

    I moved in to a new bungalow a few weeks ago. I put my heating on for the first time at the weekend I noticed that two radiators were not getting hot. My first thought the TRV’s must be sticking as the system is not even a year old. I removed the head of the Thermostatic Radiator Valves and...
  5. B

    WSP Gold CH Pump

    I have a Powermax 155 Boiler and had a few problems with it recently. My latest breakdown is the CH pump has stopped working. I managed to get it going for a few weeks by every few days removing the main part with the allen key and spinning the impellor to get it started again. Yesterday...
  6. B

    Powermax 155 Boiler Problem - Lights are on but won't work !

    After having boiler serviced last Sept 09-I have had countless problems with this dam unit ! Amazing I didnt service it for 3 years no problems and now its constant ! My latest problem is that my boiler wont start. The lights are on the timer, the pipes in the boiler are very hot as...
  7. B

    Powermax boiler 155 - How to refill with water

    Can anyone help please ? This morning I drained my system to replace a thermostatic valve. I then put the ball cock down to refill the tank, bled the radiators whilst they were refilling... But I am certain I made mistake having the boiler on whilst it was refilling. Heat was coming out...
  8. B

    How to remove a Danfoss Randall RAS-D thermostatic valve

    I have a Danfoss Randall RAS-D thermostatic valve which I cant remove. I need to do this as I have a stuck TVR. I have looked on the danfoss tech sheet but it doesnt actually tell you how to remove the head of the valve to get to the TVR !! Not sure whether it comes off by the black...