  1. F

    Where to cut drywall for doorway

    I am in the process of widening a room and moving the doorway. The position for the new doorway partly overlaps the existing stud wall and partly overlaps the new section of the wall (still to be constructed). The plasterboard has been completely removed from one side of the wall. On the other...
  2. F

    Joists under new bath

    I am looking to fit a new bath in a different position to the old bath in our ensuite on the first floor. The bath will be parallel to and over a laminated joist. This joist is about 2.0m long and is carried by a I-joist at the end I've uncovered. I suspect the other end is also fixed to an I...
  3. F

    New branch into soil stack

    Hi I'm looking to relocate a toilet in an ensuite. This ensuite is adjacent to and shares a soil pipe with another ensuite. Current soil pipe setup is thus. WC2 is the one being moved. Would connecting WC2 into what is currently the dry part of the stack as per diagram below be okay and...
  4. F

    Changes to internal soil stack

    Hi I'm hoping someone can confirm that the changes I'm planning to make to my internal soil stack meet regulations. The existing stack has an offset in the floor void of the 1st floor of my property. The upper section leads up to an AAV in the loft. There is a toilet connected to one of the...
  5. F

    Smeg dishwasher fault

    Dishwasher model: DWI 710E1 The dishwasher is repeatedly stopping shortly after starting the cycle The lights indicate a 'E2' fault - safety pressostat intervention. According to the manual, the defect can be caused by: - defective pressostat level - difficulty to connect the pump or...
  6. F

    How to pack underneath edge of plywood floor

    Thanks in advance. I have karndean flooring laid on plywood. There is a step down from this floor along one edge. The flooring bounces at this step, causing the hidden beading on the plastered edge to flex and crack the plaster. I have removed the decorative metal strip to reveal the...
  7. F

    Re-assembling shed

    This may turn out to be a long post so please bear with me..... I have a fairly standard (cheapish) apex type shed measuring 6 x 10 feet. I have dismantled it to renovate it as some of the original floor bearers were pretty rotton. I'm now at the point of re-assembling the shed but I...
  8. F

    Work on Menvier alarm

    I'm looking for a little advice. I have a Menvier TS690 alarm which has two Netlcd keypads connected to it. I have the engineer code. I need to do two tasks relating to the alarm: 1. Change the mains supply cable. 2. Move one of the keypads from one side of a door frame to the...
  9. F

    Help Required on Fordham Cistern

    I need the help of you knowledgeable folks. I have a Fordham Flush Panel cistern, the one with the plunger on the top. It flushes okay. However, on the majority of occasions the plunger doesn't rise back up again without the persuasion of a few gentle thumps on the front of the cistern...
Back