Search results

  1. W

    landlords gas certificate

    This only applied to open flued appliances. NCS no longer exists.
  2. W

    Why is my DHW lower than stated?

    1800 litres? 1000 litres? What size bath have you got? :) 10 litres a minute would take 3 hours to fill your mahoosive bath.:censored:
  3. W

    Vaillant boiler not hitting target temp

    Various settings (appliance configuration) can/should be changed in order to suit the system Ie: pump/anti cycle time etc etc. If you’re not sure then leave it.
  4. W

    Vaillant boiler not hitting target temp

    Check D.00 isn’t set to ‘auto’.
  5. W

    How to find leak in pressurised CH system?is it possible?

    Dependant on which type of fluid used. Are you familiar with the different types of manometers used?
  6. W

    Gas tightness test on u40 commercial meter

    Although the answer won’t be forgotten.;) U40 is one huge meter.:)
  7. W

    Gas tightness test on u40 commercial meter

    Post up ALL the necessary information required in order to calculate the test time and I’m sure someone will help.:) I won’t be holding my breath.:ROFLMAO:
  8. W

    Honeywell R6660D to Hive Receiver - not firing up boiler

    The parameters were obviously changed from heating to cooling
  9. W

    Honeywell R6660D to Hive Receiver - not firing up boiler

    Terminal C would not have been used on the R6660D receiver, nor would it have been a neutral( should of been sleeved). Terminal A would have been used in order to switch voltage through B.
  10. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    I’m sorry Stem but the above wiring diagram is incorrect (it won’t work).;)
  11. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    You do slip up from time to time which proves google is not always your friend.;) You should have known when looking at the photo that the system is fully pumped and obviously not to be taken at face value. You give sound advice with regards to the wiring procedure for a simple nest...
  12. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    I do hope so as this is what I do for a living day in and day out.;) Quite simple really. Terminal 1 of time clock supplies voltage to boiler/pump/grey and orange MV. Terminal 2 of time clock supplies voltage to brown wire of MV (MV motor). Live and common are linked together at time clock.
  13. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    The HW and CH are fully pumped to which is obvious when looking at the photo.
  14. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    I’ll leave it to the professional (Stem) to answer any questions you may have, hopefully he may confirm the advice given. (y)
  15. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    An additional two port motorised valve should be fitted to the Primary flow to cylinder along with a cylinder stat. The system will then be upgraded to an ‘S’ plan.
  16. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    The motorised valve must also be installed in a position so as to leave an unrestricted path for the open safety vent.
  17. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    The system you have is fully pumped. The ‘C’ plan uses gravity fed primaries (HW) with pumped heating.
  18. W

    Nest Learning Thermostat 3rd Gen - C Plan Heating System? Help!

    Certainly not a ‘C’ plan looking @ those photos.
Back
Top