Search results

  1. M

    Should I return this mitre saw?

    I've just bought a Metabo KGS 305M, a 12" compound sliding mitre saw. It's a beast of a machine, but will handle sleepers with ease, which is one significant reason for purchase. I've adjusted the fence; no problem. But the vertical is off by about 1.5-2º. Since it's a compound saw I can make...
  2. M

    Glue for PVC false glazing bars/muntins

    Hi Folks I have some PVC glazing units with "false muntins"; i.e. PVC stick-on bars. On the sunny side of the house, the bars are dropping off (units are 15 years old). I assume that the PVC was originally self-adhesive. I have managed to clean the glue reside off the windows. The PVC backing...
  3. M

    Another ... retaining wall

    Hi. Looking for some advice please. Some of my boundary fence posts have rotted and need replacing. The issue is that there’s a difference in height of about 50-60cm between my ground and my neighbour’s ground. The original “retaining wall” from when the house was built (in 2004) consisted of a...
  4. M

    3 core and earth colour coding

    Hi I'm replacing the wiring to my attic light switch with 3 core and earth so that I can use a neon switch; which of course requires a neutral. Obviously this isn't the conventional use of this cable, and I wanted to check the coding for the neutral wire. From the information I can find, grey...
  5. M

    Cooker location - regulations?

    Hi folks My aunt is looking to get new cupboards and work surfaces fitted in her kitchen. Although she has no desire to change or move her cooker, as I understand things she has been told that the cooker must be moved because of current legislation regarding proximity to a doorway. The...
  6. M

    FCU height covered by accessibility regs?

    Can someone confirm that a switched FCU doesn't count as a "switch" for the puposes of the sockect/switch height accessibility building regs? I can't find anything that specifically mentions FCUs. The appliance (additional lighting in an integral garage) will be controlled by a separate switch...
  7. M

    Chipped brick repair

    In drilling a hole through to the outside wall, I've managed to break off a piece of the face of the brick - full height and about 6-7 cms across. It's a very clean break, but the piece is fairly fragile (about 10-12 mm thick at most). I want to cement it back in place, but anything...
  8. M

    Just checking ... immersion heater spur?

    Happy and Safe New Year all. I have just installed two security lights (150W each) that I have not yet connected, with cable runs into the loft. There are currently 11 light fittings and 2 extractor fans on the upstairs lighting curcuit, so if I connect the security lights to the upstairs...
  9. M

    Two-way switches ... break-before-make ?

    Are domestic 2-way (light) switches break-before-make? If so is it acceptable to reply upon this as a method of "disconnecting" from one terminal before connecting to the other? I'd ideally like to use one to switch the live feed to a PIR to the live feed to the light which the PIR controls...
  10. M

    To tee or not to tee ... bend radius

    Is the bend radius on a "normal" 20mm conduit tee too tight to take two 2.5 T&E cables along each arm? The radius needs to be 31mm, but it looks very tight in the picture I have ... I'll know when they turn up on my doorstep .... but I'm sure someone here can tell me before then.
  11. M

    Alarm interference

    Hi I want to extend the ring main within my (integral) garage. The best route is to run conduit just below ceiling height. However, half-way along my "wall of choice" there's a pattress at the end of an alarm cable (new house - alarm not yet installed but wiring already in place) where the...
  12. M

    Security lights - advice on cable run please

    Hi I'm about to install a couple of outdoor security lights. For one of them I'm able to access the back of the lamp going straight through the exterior wall. The other requires a cable run vertically down the outside of the house, with the run originating in the loft. I can't find any...
Back