Search results

  1. C

    Oil boiler oil leak under combustion chamber

    My Trianco Contractor is 11 years old. For a while now it has smelled 'oily' when on, and at the last service I mentioned the slight oil show which was to the side and just below the combustion chamber. He didn't seem to think much of it. I asked if it was due to 'over fueling' , ie un-ignited...
  2. C

    Mixer tap washer replacement

    yes, I know , mixer taps ... I've isolated the tap - thankfully installed with isolater, removed the grub screw which hold the tap end on but it doesn't want to move. I assume remove the grub screw and then should be able to slide the chrome cover off but it won't budge. I'm reluctant to...
  3. C

    Panasonic NN-CT585 combi microwave doesn't fully heat up

    This is our second one, gave the first to our daughter. Everything works except temperature control on convection. It signals 'ready' on heat up when it's only about 50 degrees. The grill still works ok and that's the same quartz heating elements for the convection. I checked the thermistor on...
  4. C

    Shallow tarmac repair instead of cutting and cold press

    After my drive was laid, the installers had to 'repair' a section but it was badly done and I was left with patches which were 10mm below the overall flattened surface. I wasn't prepared to do any deep cut and fill with cold press tarmac and wondered about getting bitumen block to melt and...
  5. C

    Replace glass on old upvc door

    I have an old upvc door with leading externally and internally in the double glazed unit and I want to replace all this with a georgian bar window to match the rest of the windows in the house. The problem is, the glass is fitted with a square section 'beading' with a rubber seal , and I don't...
  6. C

    Condensation on LAGGED expansion pipe in the loft

    ALL the pipes in the loft are lagged with the standard polythene sleeves. There is one vent pipe into the cold water tank which is dripping with condensation inside the sleeve. The pipe rises from floor level to the height of the tank , about 12 feet since the tank is right in the apex of the...
  7. C

    Perrymatic Jetstream Mk2 Pressure reset button ?

    Neighbour's boiler had cut out due to low water pressure. I have re-pressured the system, but presumably I need to reset the boiler itself. Big black box on the boiler has the thermostat knob for water temperature and there is also a chrome nut and shaft mounted on the box with a metal pin in...
  8. C

    upstairs radiators get warm when the hot water is one.

    I have an old oil-fired Trianco boiler. Separate circuits for CH and HW , no diverter valves anywhere. Boiler downstairs in kitchen. Hot water tank upstairs in airing cupboard. Towel radiator in bathroom is part of the hot water heating circuit. Since last year , radiator on landing now gets...