Search results

  1. Robin0577

    Is the electrical industry built on a house of cards?

    What John said, mostly Smart meters do report a loss of supply, but obviously not the reason for it. However if one smart meter reports a loss of supply while others in the area don't, that could be seen as in indication of either a fault or tampering. Modern plastic cutouts that are in good...
  2. Robin0577

    Megger vs Insulation tester?

    Megger is simply a popular brand of insulation tester, the "Hoover" of insulation testers if you like. You should also be aware that insulation testers are available as just that, but more commonly these days, they're combined into multifunction testers that also do continuity, loop impedance...
  3. Robin0577

    Identify connector

    There are hundreds of similar types.. Are you just wanting to replace the single missing contact, or the whole thing? The contacts are usually sold separately. If it's the whole thing, you'll need to know; The EXACT dimensions, especially the distance between the pins. Some are metric, some...
  4. Robin0577

    Changing Drayton LP 522 to Tado

    According to the wiring diagram for the Drayton, terminal 4 is indeed CH ON or CH NO Using a G/Y wire oversleeved for live is indeed against the rules in the UK and most of Europe, but it is done all too frequently. The colour of a wire in fact means nothing at all from an electrical point of...
  5. Robin0577

    Are these connectors man enough

    Only if you are going to leave an inspection hatch in the wall. Screw terminals are NOT permitted by BS7671 for inaccessible joints. Wagos are, provided they are in a suitable "maintenance free" approved enclosure. An approved enclosure with cable strain relief... Not a rubber glove. If it needs...
  6. Robin0577

    32A Industrial socket for cooker?

    There is some room for argument on this one. The regulations forbid the use of un-shuttered sockets on domestic installations, however many people, myself included, believe that a switched interlocked industrial socket provides a safety function at least equivalent to the shutters on a standard...
  7. Robin0577

    Old power cable needed

    Pretty sure that's a long obsolete connector, you might do better asking here.... https://www.vintage-radio.net/forum/index.php
  8. Robin0577

    What Consumer unit should I get

    Well, if you have to buy a budget beard, I suppose BG are better than some of the other cheapo options. Personally I would go for something a little more expensive such as Hager or Schneider. 4 way is unlikely to be enough for modern needs though, unless for a very tiny flat. You should...
  9. Robin0577

    How to Move internet fibre broadband?

    @SimonH2 My understanding is that they use cables which are pre terminated at the distribution end to avoid having to splice up poles etc. but still splice at the customer end. The distribution end plugs into pre assembled G-PON (gigabit passive optical network) splitters such as these...
  10. Robin0577

    Generator to run water pump 150m away, voltage drop

    Well, if we calculate for the worst case.... The generator can only produce 2.2kw so the load can't be more than that, or the generator would be noticeably unhappy*. A generator that small will almost certainly be single phase. With a distance of 150m and using SWA cable buried in the ground...
  11. Robin0577

    3 phase 3 pin to commando single phase

    You cannot do this with a simple cable adapter. As everyone else has pointed out, you have no neutral available. In theory, it can be done with a transformer but that would be very impractical due to the size, weight and cost of such a thing. Out of interest, I looked one up, it was about 50kg...
  12. Robin0577

    SWA on a fence

    Of itself? No, it probably doesn't. If that, and the state of the fence are taken as indicative of the general standards of workmanship, safety, site maintenance, etc. then perhaps it does.
  13. Robin0577

    Ceeform outlets in a household or similar premises

    No, I wouldn't consider just a flap to be adequate. I don't think the dictionary definition of a shutter matters here. Perhaps the BS1363 definition would be the one to go with? I don't know the actual wording of that but I'm sure it includes some mention of the mechanism being operated by...
  14. Robin0577

    Ceeform outlets in a household or similar premises

    I'm inclined to agree with the view that whilst a switch interlock mechanism doesn't equal a shutter, it does satisfy the same safety function, i.e. that curious little fingers can't poke things in and make contact with live parts.
  15. Robin0577

    Selling house - but consumer unit certificate missing. Illegal install?

    Paperwork aside, a Hager RCBO board doesn't sound like doing it on the cheap, that's decent stuff not some DIY store special offer.
  16. Robin0577

    recording from SD card onto CCTV cameras

    In my experience, which is admittedly very limited with cameras, the recording function of the SD card can be set in several ways. These are the options on my Hikvision cameras... Motion triggered, as Harry suggests, which will need a clear image to work, as Harry points out. Triggered by some...
  17. Robin0577

    recording from SD card onto CCTV cameras

    I have no knowledge of those specific cameras, but if they behave like most other IP cameras or for that matter, like most other IP controlled devices then the procedure will be something like... 1. Ensure the device is returned to factory default settings. This usually involves holding down a...
  18. Robin0577

    light switch auto-off after set time

    There are more attractive and less bulky electronic delay switches available which do the same job as the Elkay BUT many of them require a neutral to be available at the switch position, which is often not the case with standard domestic lighting circuits. The Elkay ones do have the advantage of...
  19. Robin0577

    Is this a simple install?

    I quite agree it's not a perfect solution. There MAY even be enough space inside the OP's new fitting to accommodate a Quickwire there, I can't tell from the photo. In a class 1 fitting I'd be happy to use terminal blocks or Wagos contained inside the fitting itself, but in this case that would...
  20. Robin0577

    Is this a simple install?

    Quickwire is about the slimmest I can think of... https://www.quickwire.co.uk/product/quickwire-switch-load-junction-box/ Even then, a little making good may be required. The downside of Quickwire is that you have to select the right type in advance, they can't be reconfigured on site.