  1. S

    fused spur

    i have taken a fused spur from the ring main. which is fused down to power a light under the stairs. from that fused spur can i use 2.5 cable to another fused spur and fuse it down, then 1.5 cable to supply an outside light.
  2. S

    kitchen work top/howdens

    has anyone got any idea on how to remove a scorch mark on the kitchen worktop, doh
  3. S

    fire doors

    under current building regs when hanging a fire door do i need to put in a intumescant strip as well as a fire door stop.
  4. S

    2 way lighting

    if the supply is going to the switch how does the 2 way lighting work regarding upstair and downstairs lighting. i have been racking my brain and i must be missing something. i can get the downstairs switch to turn upstairs on and off, when the landing light is off the switch upstairs turns...
  5. S

    lights and wall lights

    i am changing my front room light for new, and putting 3 wall lights up. all to run from the same switch. question is that the light centre light has only got the switch live to it and the live supply feed to the switch, what is the best way to wire up the wall lights to make sure they come on...
  6. S

    bathroom fan heater on wall

    the fan heater that is supplied has already got the wire attached and does not need earth, so only blue and brown wires. can i wire this into a fused spur in the bathroom in zone 2 on the wall. or does the fused spur have to be outside the room? If the spur has to be outside how do i extend...
  7. S

    lamona ceramic hob t1713

    has anyone experience there lamona rings going off, brings the water to the boil then turns off, other rings stays on and some dont even stay hot,another ring get to a mild temp and does not get hot this is a brand new hob????
  8. S

    cooker/hob supply

    hob requires 30amp supply and the oven requires 20amp supply. question? hob is on one side of the kitchen and is supplied with 30amp from the ccu by 4mm cable and the oven is oppisite. can i use the main cooker switch to supply both appliances,
  9. S

    outside socket

    at the moment there is an outside power supply to the garage and light, this is supplied via swa cable. now the swa is attached to the ouside of the house connected into a sealed junction box ip rated. can i change this to an outside socket but still keep the power to the garage and light etc.
  10. S

    garage supply

    What supply can i use for a rcd garage fuse unit. at the moment there is a old type fuse bs3036, this is supplied by 2.5 m cable then 2 fuses are run of that. can i do the same by using the original 2.5 m cable into the rcd and the connect up the light/socket radial circuit on b6 and b16 mcb.
  11. S

    outside socket

    can i take a switched spur of a ring main, and then connect to a outside socket, directly onto the outside wall. as i will be using a ring main from the living room do i need to inform BC. Do i have to inform BC for a like for like in a kitchen. no alterations or new circuits. a bit of a catch 22
  12. S

    double dimmer switch

    one side of the double dimmer switch does not turn the lights on. checked for loose wires all ok, what else shall i look for