  1. Gasescape

    Samsung American Fridge freezer

    Looking for a little assistance Model RSH1DBBP Anyone with any experience Samsung tech won’t help or share any technical info other than check plug & cable, Tripping rcd roughly twice per day, They won’t give any info on any components & only offer site visit or 25% loyalty discount off new...
  2. Gasescape

    Zafira tail/brake light issue

    Wee update on this Was a fault with the rear control box , Vauxhall mechanic has managed to get it working with a little trickery ;) Car will be traded in if I ever need to spend big bucks on it ...
  3. Gasescape

    Zafira tail/brake light issue

    Had the plug (green one) disconnected & it looks fine , no corrosion or water ingress. Is the rear control box prone to faults ?
  4. Gasescape

    Zafira tail/brake light issue

    Haven't done anything with battery ! Is it worth a try ? Not got oscilloscope :cry:
  5. Gasescape

    Zafira tail/brake light issue

    I just measured across the tracks on both sides to compare readings . Good side reading 3v Bad side reading 13v I've tried the faulty cluster on the other side & it works perfectly.
  6. Gasescape

    Zafira tail/brake light issue

    Just to clarify 3v was measured across the working light & 13v measured across non working light , measured across the bulb track. Regards the potential earth issue !!! Would an earth fault not affect all the lights on the cluster ?
  7. Gasescape

    Zafira tail/brake light issue

    I'm hoping it's a daft missed fuse , the owners manual doesn't mention split fuses & ive checked all the 5amp in the rear box ( did find out why my front charger hasn't worked for years) felt like a glorious moment only to realise it wasn't the fuse I was looking for:( I'll pull out the front...
  8. Gasescape

    Zafira tail/brake light issue

    It's the correct bulb & ive tested the cluster on the other side & it works fine. Out of curiosity if the earth was faulty why does everything else on that cluster still work ? A wiring diagram would be handy . Front lights are fine .
  9. Gasescape

    Zafira tail/brake light issue

    Driver side rear tail & brake light not working . Have replaced bulb & tested cluster on opposite side & works perfectly. Checked fuses (doesn't seem to be a split fuse set-up ) All other lights on the cluster work fine when plugged into the drivers side . Now , I've checked the voltage on the...
  10. Gasescape

    Random boiler activity noises - Vaillant ecoTec pro 28

    Get the installer back & get him to look at the S codes whilst the issue is happening or look at the manual yourself for S code access & monitor yourself
  11. Gasescape

    Random boiler activity noises - Vaillant ecoTec pro 28

    Does the tap symbol appear when this is happening & why did the installer fit a combi and leave the cylinder in ??? Sounds like a dead leg to me .
  12. Gasescape

    Vaillant ecoTEC 831 with Timerswitch130 and Honeywell DT92E

    Is the Honeywell receiver not wired wrong ? Both lives & B are linked !!! Should it not be lives & A linked & switching on B ?
  13. Gasescape

    Potterton Back Boiler has hot radiators but no hot water

    I'd go +1 with Dan & the rest,choked cold feed on the coil return if that's were it t's into... Enough to stop flow through the coil , I'm sure you'll find in a month or 2 if left you'll have a total blockage and the system won't fill ..
  14. Gasescape

    Singing pipes / water hammer

    Do they sing the same song or is it always different song ? :D
  15. Gasescape

    HELP PLEASE vaillant turbomax vuw 242/1e,282/1e

    If they just keep turning I'd agree with the Bunnyman , have you trying pulling them out ?
  16. Gasescape

    VAILLANT HELP NEEDED! Controllers

    Think you might need a vr61 , but best wait for a bunny to come along & give a definitive answer . :wink: Some good bunnies on here :D
  17. Gasescape

    ideal classic pilot extinguishes, smell of gas from flue

    Call a RGI , cracking little boiler probably just needs a good service/TLC
  18. Gasescape

    Potterton Suprima L nightmare

    New style pcb flashing Amber ! New pcb time I'm afraid , it thinks the boiler stat is turned off. Pretty common fault on the newer pcb's. Probably find it's pretty random then gets progressively worse .
  19. Gasescape

    Vaillant ecotec plus 428_Timer

    How do you set up the boiler to run between 9 & 5 ?