Search results

  1. T

    canon mg3250 wireless

    my printer used to work fine on my bt hub 5 , nothing has changed but it now wont connect , printer works fine with usb lead , tried re pairing wps but wont connect , downloaded canon software and when I get to the select access point it shows my network but the connect button is greyed out so...
  2. T

    gu upvc lock replacement

    Hi all , I have a gu 35/92 lock and I am trying to replace it with a split spindle lock , does anyone know of a lock that fits or will I have to buy the whole locking mechanism ???
  3. T

    potterton perfoma 28 flame failure

    It works fine on dhw but from cold on heating it usually does flame failure , from cold dhw works fine , I know it will be suggested low gas rate but surely that would affect the dhw as well , any pointers great full received .
  4. T

    Upvc door lock

    I have a upvc door that the latch is operated by both handles , I want it so that the latch can only be opened from inside on the handle and would need the key from outside , at the moment the key does not operate the latch just the handles . Do I need a complete new lock unit or can it be setup...
  5. T

    Worcester greenstar 40 cdi loosing pressure

    The boiler and all pipework rads etc are 5 years old , the boiler is needing to be pressureised three times a day , there are no leaks on any rads , valves etc . The expansion pipe is not dripping at all . It seems to lose pressure when the hot tap is being run which would point me at the dhw...
  6. T

    xplelair sl100ht bathroom extractor fan

    I have fitted the above fan and wired it just to permanent live and permanent neutral via a fused spur , I dont want the option to just pull a cord to turn it on as well , I just want it to operate on humidity . Since powering it up the fan is just staying on constantly , altering the two...
  7. T

    40 cdi loosing pressure

    Worcester 40 cdi is loosing pressure but has no leaks , if I fill the boiler to exactly 1.5 bar and then run the hot tap for 5 mins you can see the pressure gauge is loosing pressure , when it switches back to heating it has definately lost some pressure , is this going to be the DHW heat...
  8. T

    Protherm 80EC pcb fault help

    I went to this boiler last and it was completly dead , nothing on the display , pump not running or fan , main pcb was burnt out ( the transformer ) new pcb ordered and fitted , now the display comes on and the pump runs but nothing else happens , fan doesnt run , +volts to the fan but no...
  9. T

    Valliant combi compact vuw gb236e

    Hot water is fine with no issues , today the central heating isnt working , what it is doing is coming on ,the temprature is rising very quickly , satisfying itself and switching off , neither heating pipe gets hot at all , Pump gets very hot and is very corroded on its casing , I am suspecting...
  10. T

    airlock in waste pipe

    I have a sink which does not empty upstairs . The waste pipe is horizontal with a 2m fall . It goes vertical for 3m then goes horizontal with a fall on it 3m with a tee half way along to another basin then it drops into a saniflo, The second basin empties fine but the upstairs one takes...
  11. T

    Drayton digistat

    I have a drayton digistat , which is now being tempremental , the reciever gets the signal from the thermostat and the "heating " light comes on but the boiler doesnt , checking the wires with a multimeter and the unit isnt switching inside are these units prone to a relay failure inside ???? It...
  12. T

    baxi 105 instant he

    boiler is dead , ie power lights are on pressure is ok , turn on heating or dhw and demand lights come on but the only thing running is the pump , no voltage to the fan and no flashing lights , it looks like pcb is gone , oh stat seems ok , anything else to check ??
  13. T

    kinder oasis oxy pilot unit

    I have been to one of these and proved th oxy pilot unit is faulty it is the kf130 with a wall mounted three switch unit to operate the fire , I have looked on the usual place i use for spares but they dont list it ( gas appliance spares preston) but I will call them tomorow , are these a...
  14. T

    Bosch microwave knob

    We have a built in bosch microwave , the time select knob is flush and should pop out when pressed , this now does not happen the knob can still be used to alter the time while it is flush but i want to know how to make it work as it should , will something have stuck and is it easily accesible...
  15. T

    Neff washing machine doesnt empty

    If we put the machine on a cycle it gets to the emptying part and then comes up witht the error "3" , we have checked the drain which is clear . if we turn the machine off and turn the control knob to number 2 pumping , it will then empty the machine so I know the pump works is this going to be...
  16. T

    Shower pump possible

    Cus originally had a venturi shower fed of mains pressure cold and hot from the cylinder , there is no way without major disruption of getting equal pressure feeds to the shower , so new normal valve fitted with a pressure equalising valve , shower pressure is now pretty poor , is it possible...
  17. T

    Shower with unequal pressure feeds

    Cus wants to replace his venturi shower which was fed via mains pressure cold feed and a hot feed off the cylinder . He wants just a normal bar type shower valve . There is no way to convert the cold feed to a tank fed cold . Can a pressure reducing valve be used to make the two pressures equal...
  18. T

    windows xp crashed

    pc crashed yesteday and I had to use the recovery cd , then reinstall everything , but now I cant use windows update , I cant install ie8 and when you tell the pc to shut down it just hangs !!!!! , I dont want to format the hdd and then reinstall as the wife has loads of music on the pc she...
  19. T

    New syphon for push button toilet

    I am going to look at a toilet that is constantly running into the bowl , not sure of the make as I havent been yet , but it is a 5 yr old twin flush toilet with the button to flush it attached through the cistern lid to the syphon , If I have to replace the syphon where is the best place to get...
  20. T

    Shower loosing its water seal

    Went to a guys house whose shower smells every week or so. The shower never gets used and loses its water seal . The shower is on the ground floor on a 40mm waste pipe with a basin teed into it then it goes straight into the soil pipe , distance from shower to soil pipe is 2m. The soil...
Back
Top