    Where is the mesh filter on this inlet control group?

    Sorry John, l know what pressure it should be at. I was curious as to whether the vessel had any charge in it? After reading Harrys last post I think he meant relief valve and not reducing valve. Burst and flat vessels are by far the most common cause of relief valves being activated and...
  2. J

    Where is the mesh filter on this inlet control group?

    Are you sure the pressure reducing valve was letting by? Normally when these things go wrong, the symptoms are low pressure. Out of curiosity, what pressure was on the expansion vessel when you de-pressurised the cylinder?
  3. J

    Ferolli combi boiler. Hot water working but no heating

    The old F24 was similar to the Modena SE. Bi thermal heat exchanger so no diverter. Cold in to the main hex and HW out the other end. If the heating hasn’t been on for while then the pump is probably just needing a tap with a hammer. Another thing to check is the power plug going into the pump...
  4. J

    Replaced Danfoss FP715 with CP715 now no hot water.

    I know it might seem obvious, but did you try resetting the old one? The R/S button left of the HW select switch.
  5. J

    MDPE pipe for pre heating water for unvented cylinder - safe?

    The chimney shouldn’t get that hot. If anything, the further away from the heat source, the cooler the masonry should get. Do you get the chimney swept annually, does it have a metal liner? I suppose your sweep would have highlighted a problem if there was one. On the mdpe pipe conundrum, I’d...
  6. J

    MDPE pipe for pre heating water for unvented cylinder - safe?

    Sorry to cast a shadow on your heat recovery contraption, but if the chimney breast in the attic is getting to 40°C, does this not give you any cause for concern?
  7. J

    funny guide on a (presumably electric!) boiler

    Nothing against combi boilers, it's the drivel that's being spouted I'm referring to.
  8. J

    Towel rail fixings for triple skin plasterboard walls

    If the wall is being tiled, I'd just drill into the tile and use a rawl plug with a bit of sticks like Shiite on the back of the bracket. Hung loads like that and none have fell off. Well, none that I've heard about.
  9. J

    Vokera Vision 25C

    That's weird Ian, I've never seen the throttle type valve on a vision. It's always been the 3 way type. If the fault has only happened after BG had serviced it, perhaps it's just the flow rate needing adjusted. It could be the plate thou the way you've described how the boilers behaving. The...
  10. J

    Solid fuel boiler making kettling sound

    Make sure the switch for the immersion heater isn't switched on. The thermostat on the heater might not have an over heat cut off switch which would Explain the kettling noise. If the problem is at the stove make sure any air control thermostats aren't jammed open. Bits of coal cinders and...
  11. J

    CO risk with all boilers?

    Calvados, do you have your gas appliances serviced? Fitting CO alarms is a good idea but regular servicing, particularly on open flues appliances is essential.
  12. J

    bubbling air in central heating pipes

    Your systems either got a big leak somewhere or it's drawing air in through the vent pipe.
  13. J

    Chimney flue installation

    http://www.hetas.co.uk/find-installer/
  14. J

    Baxi Combi 105e DHW fine CH not so good

    Check the gauze filter in the return isolator. Also, as above.
  15. J

    Plumbing. Bending pvc coated copper pipe

    The plastic coating only acts as an insulation and can be removed. 10mm is plyable to bend without the bending machine. If the pipe work is below the floor then just bend it over your knee. If it's going to be visible above the floor then just peel back and remove the insulation and use the mini...
  16. J

    2 zone heating system

    Take the grey wires from the 2 ports into one side of what you refer to as the jumper lead. Connect the orange wires from the two ports into the other connection on the jumper lead (link wire). You'll need to power the valve motors (brown wires) through prog/stat switches. Does the boiler have a...
  17. J

    Potterton Profile 60E shuts down

    You need to check for voltage on the pump first.
  18. J

    Differant opinions?!

    The first guy sounds like a bit of a chancer. If there's no reason why the boiler can't be moved says enough. It's your house, and it's what you want. He's looking for the easiest solution with maximum profit.
  19. J

    Potterton Profile 60E shuts down

    The ball cock on the feed and expansion tank might have jammed or the cold feed pipe could be blocked.