  1. M

    Overboarding ceiling

    Hi I want to overboard a woodchip ceiling with 12.5mm plasterboard and I've chalk lined joist centres for fixing screws. My questions are: 1) Should plasterboard run 90 degrees to the joists? 2) If above is correct will the ends of plasterboard need to finish on a joist or will it not matter as...
  2. M

    Angled mouldings?

    Hi A few years back I could purchase plastic angled mouldings to stick onto external corner walls in rooms after decoration. I'm having great problem finding them now as they are good for protecting wallpaper and keeping the corners clean. Tried the usual, B&Q, Homebase but no luck. The...
  3. M

    Conservatory roof reduce glare

    Hi We have a small conservatory with a polycarb roof wich is fine except when sun shines the glare makes it very difficult to see PC screen (PC/internet is in here no room for it elsewhere). My question is; is there a paint or a film that can be applied to the polycarb roof to reduce glare...
  4. M

    Condensation in loft

    Hi Wonder if any of you roofing gurus can advise here. Moved into a bungalow during this summer which was built in 1981 and the roof has plaster board sarking with felt and roof tiles. During this recent frosty weather I have noticed a musty smell in loft, the plaster board sarking seems...
  5. M

    Hairline cracks on woodchip on ceiling

    Hi I wonder if anyone has cam across this and found a fix. Just bought a 30 year old bungalow that is all woodchip walls & ceilings. We're stripping the paper of walls but intend to leave ceilings as the paper looks fine (except one room) and freshen up with emulsion. The problem is the living...
  6. M

    Vokera Linea 24 DHW issue

    Hi This problem started with the boiler not firing and going out on Fault 01. The main PCB (board with transformer & relays on it) was replaced albeit some wiring/jumpers on new board had to be change to allow the board to be compatible with the boiler. Boiler installed 1999. Since then we...
  7. M

    Vokera linea 24 issue - update

    Hi I posted earlier about about a problem with boiler not firing and going out on Fault 01. The main PCB (board with transformer & relays on it) was replaced and boiler would fire up OK but flame would go out after approx 8 seconds then flash 01 fault. It turned out the wiring/jumpers on new...
  8. M

    Linea 24 01 fault

    Hi I have a Vokera linea 24 about 12 YO which has a flashing 01 fault. Tried reset and boiler tries to fire, stops, tries to fire, stops, this is repeated a few times then bolier locks out on 01 with fault led flashing. I couldn't see (cover off) any sign of a flame trying to ignite. Any...
  9. M

    Triton dart mixer, cool water from shower

    Hi I have a Triton Dart thermostatic mixer for the shower fed from a Combi. The shower temp is cool when turned fully on. The hot water inlet pipe at side of mixer feels hot and hot water is fine out of HW taps. The shower installation is approx 2 years old and up to a week ago water temp was...
  10. M

    ceramic disc mixer tap

    Hi Have a dripping cold water on a mixer tap I have in the kitchen. The mixer tap has 45 degree rotation on each tap from off to on. I was expecting the drip to be caused by worn washer but no washer to be found! Turns out it is a ceramic disc tap. What is the easiest way to repair this leak...
  11. M

    Combi - What's this valve for?

    Hi Just below my Voker combi, on the 22mm CH flow & retun pipes, there is a 'T' on each pipe linking both pipes together via a 15mm gate valve. To describe it electrically; it's like a short circuit between the CH flow & return pipes with a gate valve in the middle. The gate valve is...
  12. M

    Message for Gasinayr4

    Hi Gasinayr4 Wonder if you would like to sort an issue with my Vokera Linea 24? CH fine, issue is with DHW. I live in Stewarton. I can be contacted off forum by PM: [email protected]. Hope to hear from you as this issue is doing my head in.
  13. M

    Vokera Linea 24 -now no DHW

    Hi I posted over a week ago about DHW not always being hot, now there is only a slight heat. The CH works fine no issues. Turn on DHW tap and the temp guage goes to and stays at around 34c. Turn off tap and boiler temp goes to around 68c. No matter how long I run hot water tap the temp still...
  14. M

    Vokera Linea 24 DHW issue

    Hi Had the above combi almost 12 years and generally works fine. The issue is with DHW during the winter months. Outhwith winter DHW & CH is fine. During winter (right now) the DHW seems only tepid wether it is out of the tap or mixer shower. The CH on the other hand is fine ie radiators hot...
  15. M

    Linea 24 CH not working

    Hi I have a Vokera Linea 24 combi, 11 years old which was switched to DHW during the summer, last night I selected DHW & CH but CH does not work. DHW water still works OK. There are no fault codes and green light is lit. The clock is "on" , TRV are turned up and there is no room stat. In...
  16. M

    Linea 24 DHW problem

    HI We have a Vokera Linea 24 almost 11 YO, CH works fine the issue is with DHW particularly first thing in the morning. First thing in the morning the water is luke warm, temp guage hovers aroun 30ish. Turning off the water supply shows boiler temp around 70ish degrees. A couple of hours later...
  17. M

    shower mixer tap - too cool

    Hi New bathroom installed 18 months ago with a shower cubicle, no bath. Hot water fed from combi and shower works well, good pressure etc but during winter months the shower temp is to cool. The mixer tap which I can't see a name on is clyindrical with a knob on each end, is there any way I can...
  18. M

    Zs calculation

    Hi Got my 17th test to sit shortly but stuck with a zs calc. What answer do you get for the following. Zs=Ze+(R1+R2)xMxL Ze=1.2 (R1+R2)=30.2milliohm/M M=1.2 L=25M I get the answer of 36.906 ohms but this feels too high. Any help with this will be appreciated.
  19. M

    Radiators always hot

    Hi Just took over new house, heating system 3 years old - worcester combi 28i. Just completed major redecoration where I removed and since re-fitted all rads, all bled & no leaks. The problem is; boiler 'on' & room stat 'on' all radiators are very hot, turning down TRV's seems to make no...
  20. M

    Radiators always hot

    Hi Just took over new house, heating system 3 years old - worcester combi 28i. Just completed major redecoration where I removed and since re-fitted all rads, all bled & no leaks. The problem is; boiler 'on' & room stat 'on' all radiators are very hot, turning down TRV's seems to make no...
Back