Search results

  1. T

    Occasional leak from roof tile vent

    I have 2 plastic vent tiles on my roof. From within the loft, I see that their underneath interface is a 75 mm diameter pipe, presumably to allow connectors, or just to allow ventilation. One of them is directly above the loft hatch which is lined with polystyrene on top. The other one is above...
  2. T

    Replace circuit breaker with WIFI smart metering circuit breaker

    I want to monitor how much energy our electric shower is using. The shower is currently on a Hager MTN132 B32 MCB. I assume that this Hager MTN132 B32 MCB goes on to a busbar and has a single live wire connection at the top. On Amazon and eBay, I have seen MCB's that have WIFI functionality...
  3. T

    Key operated emergency light switch for non-emergency installations

    I have an outdoor security light with a PIR sensor. I want the unit to have permanent power. It is switched from a 2 gang light inside the house on a one way circuit. One switch is for the kitchen internal light. The other switch is for the outdoor security light. People are in the habit of...
  4. T

    Identify collar/ring diverter valve for bath taps

    I am trying to troubleshoot a diverter valve that seems to be stuck, so I can only get water via the shower hose. I cannot get water through the bath taps. It is operated by moving a ring or collar. I have another one which works correctly and I think that I can hear a spring or something inside...
  5. T

    Whirlpool gas hob akm200wh sparking continuously even without button

    My gas hob sparks continuously. I am aware that the button should be kept dry etc. But even if I remove the button unit from the plug in terminal, it continues to spark. I thought that it would be unable to spark without the button. Any suggestions as to the cause? Eg. Does it indicate a faulty...
  6. T

    Seeking 2 1/2" (63mm) Euro sash escape lock with night

    I have a wooden door with a lever sash lock. The latch can be operated from both the inside and outside handle. So anyone can enter from outside if the door has not been locked with the key. I think that my old lock is a common standard size: Case size: 63 mm deep, 109 mm high Backset: 44...
  7. T

    Glow-worm Capricorn 240/6 Gas Liner Terminal diameter?

    The Gas Liner Terminal is missing at the top of my chimney. I have been advised to get one installed. Whilst shopping around I read that it is essential that I get the correct diameter fitting. I see that they come diameters between 4" and 9". Does anyone know which size it is likely to be? It...
  8. T

    Glow-worm Capricorn 240/6 pilot won't stay lit

    Hi This evening I noticed that the pilot light went out on my boiler. So I followed the instructions on how to light it. It will spark and light up, but as soon as I release the button that must be pressed when igniting the pilot it goes out. Does anyone have a suggestion as to what might be...
  9. T

    Gas boiler fire front upgrade

    I have an old back boiler with a fire front. It is a Glow worm Capricorn 240/6. The back boiler works well, but the fire front is looking dated and I would like to replace it with a new front. Does anyone know whether it is possible to buy a more modern front for it? Or must I buy a whole new...
  10. T

    Potterton Puma 80 combi pilot out after about 1 minute

    I have a Potterton Puma 80 combi boiler about 4 years old. If I light the pilot, then run the hot water, it fires up. But the flow rate stays low. Then after about a minute the pilot goes out. After that if I run hot water, it is still low flow rate but very hot. Similarly, if I light the pilot...
Back
Top