Search results

  1. N

    New Circuits and CU change

    Hi bas, The assumptions are that it is one compentent registered person who can self certify and notify LABC with test results. Existing installation would be tested prior to CU change and that the test results are ok. the course I am doing is Bsc Building Surveying. Cheers....
  2. N

    Hall Lighting - two way switch

    Hi, Try the reference section of this forum, there are some great diagrams for two way switching that should help. Whatever you do, turn the leccy off !
  3. N

    Firewire problem or video camera?

    Hi, I have installed a firewire card so that I can connect my Sharp miniDV camera and get the videos off of my camera. The problem is that I can't. When the camera is plugged in and turned on, XP doesn't recognise the camera at all. It recognised it once and then it disappeared. Can someone...
  4. N

    New Circuits and CU change

    Hi, as part of my course I have to make a project plan to add a ring and a lighting circuit to a garage extension and also change the consumer unit which has existing circuits connected to it. The bit I'm not sure about is when to do the CU change. The existing CU is in the garage extension...
  5. N

    BTU Ratings

    Thanks for your help...I'll let him know... Cheers..
  6. N

    BTU Ratings

    Hi, my next door neighbour is installing a combi central heating system himself and he wants to make sure he gets the right kind and size of boiler. The total BTU for all of the radiators is 41k BTU's. It's a 3 bed semi. Could anyone please suggest the best make of combi boiler to get and...
  7. N

    What is best for ground cover

    Thanks....
  8. N

    Running cables in a stud wall

    Thanks very much everyone, I think I'm going to try the notching out idea. One more question though, if I am running the cables that close behind the plasterboard, do I need to protect the cable? Cheers....
  9. N

    Running cables in a stud wall

    Thanks andy, if there was framwork in the way, would this mean remving sections of plasterboard?
  10. N

    What is best for ground cover

    Hi all, I have a ditch that runs down the side of my house that never gets any water in it. It is currently full of brambles that we are clearing. What would be the best type of ground cover to cover the entire ditch? Thanks...
  11. N

    No water from bleed valve

    Thanks, I'll try that tomorrow. Cheers.
  12. N

    No water from bleed valve

    Hi all, I have a small radiator that is warm at the bottom but not at the top. I have tried to bleed the radiator but nothing comes out not even air. Is this likely to be an air lock? Thanks..
  13. N

    Running cables in a stud wall

    Hi all, I want to add a socket into my living room and I'd like to conceal the cable. Does anyone know how I can run the cable through the framework of the stud wall. I need to go about 3m along from the existing socket. Does it need to be run in conduit? Also what is the best type of...
  14. N

    BS3036 Breaking Capacity

    Does anyone know what the short circuit capacity of a BS3036 fitting is and what the maximum PFC can be for this type of protection? Thanks..
  15. N

    Electrics to Garage

    Thanks....
  16. N

    Electrics to Garage

    Thanks...
  17. N

    running mains cable

    You can go vertically from the socket and run the cable horizontally along the top of the wall as long as it is no more than 150mm from the ceiling and then back down to a socket.
  18. N

    Electrics to Garage

    Can anyone explain why a 32A MCB is not suitable for 2.5mm T/E when the majority of domestic ring mains and radial circuits use it ?