Search results

  1. S

    Adding MAX 4 Reader to Group - not working as expected

    Galaxy GD256 has 3 Groups: Group 1 - Main House (Main Panel & Powered RIO's) Group 2 - Workshop (Powered RIO) Group 3 - Garages (Powered RIO) I have added a MAX 4 to the RIO in Group 2 Garages. It's addressed onto the Galaxy GD256 with no issues and Access Control is enabled. I've assigned the...
  2. S

    Galaxy G3-520 & AG8 power issues

    While working on my Galaxy panel recently I had to cut the power & disconnect the battery as I was adding in some new keypads. Before cutting power I spared out the AG8 bell in the Engineering Menu>Outputs menu. Verified the alarm did not sound by triggering an intrusion (Part set then open the...
  3. S

    SDS bit snapped in brickwork - what to do?

    I was in the process of drilling a 6mm pilot hole in the facia brickwork beside my back door. The bricks have a smooth fired finish. I figured i'd put in a pilot first to minimise the finish coming away. Then proceed with larger bits up to the final hole size of 20mm. The 6mm Bosch SDS plus bit...
  4. S

    Galaxy G264 - Completely remove unused groups

    My original Galaxy Alarm was comprised of 5 Groups: A1: Main house A2: Workshop/Garage 1 A3: Garage 2 A4: Garage 3 A5: Shed I've since knocked down the separating wall between Garage 2 & 3 and also demolished the Shed. So now system looks like this: A1: Main house A2: Workshop/Garage 1 A3...
  5. S

    Honeywell AG8 manual

    Hi folks, I've lost the manual for my AG8. I've found an AG6 manual online but can't find the AG8. Are these these same? If not, does anyone have an AG8 manual in pdf they could send me please? Cheers -s
  6. S

    Galaxy 3 keyprox - disable chimes in garages

    System is a Galaxy G3 with 264 Main board upgrade . System is comprised of: * Group 1 - Main house with 3 MK8 keyprox * Group 2 - Workshop with MK7 keyprox * Group 3 - Garage with MK7 keyprox * Group 4 - Garage with MK7 keyprox Each time the main house is set or unset, the 3 keypads in the...
  7. S

    Siemens SSA61 0-10V radiator values

    I've picked up about half a dozen of these to control my radiator valves. I'm modulating these with Crestron 0-10V controllers (DIN-4DIM-FLV4). Measuring the controller output these do indeed measure 0-10V exactly when modulating the valves but the valves do not operate. I'm using the supplied...
  8. S

    Galaxy G3-520 - Alert! Enter Code - then nothing

    Greetings, Haven't been here for a while due to working abroad for a bit. My wife has been pestering me for a while now as she had to completely disable the Galaxy while I was away. This is a DIY install (unsupported) and has been working fine for many years. Recently we've been getting an...
  9. S

    0-10V wired TRV's

    Anyone know some good brands of 0-10V TRV's? These need to be wired and ideally 24V ac/dc supply. I really like the look of the Honeywell M4410 series and these would fit my requirements but I cannot find a UK supplier for them on google. If anyone knows where I can get these or a suitable...
  10. S

    PIR's & smoke detector recommendations for Galaxy G520

    Title says it all. I'd like to integrate some smoke detectors into my system and fit a PIR in most of the rooms. What are your preferred brands/model no? Thanks -slip
  11. S

    Door Force error Keyprox (Max)

    I am getting repeat alarms being triggered. It looks like one of my Keyprox is generating the error. On the keypads I get the following error: DOOR FORC A1 On inspecting the logs it I see DOOR FORC MAX 20. This is the address for one of my keyprox's. I have checked the keypad and can't see...
  12. S

    New Galaxy Dimension - a few questions

    Having looked at various forums I figured to post here as there seems to be a lot of worthwhile experience without some of the attitude I have seen on some of the 'professional forums'. So greetings everyone - first post. I bought a new Galaxy Dimension G520 off ebay. Although I don't work in...
Back
Top