Search results

  1. S

    Another pump continuously running...

    Hi guys hoping for some advice from the experts before I call someone in. S-plan system, has been working ok for a few years. Grundfos UPS2 Pump gets power via the boiler (Vaillant EcoTec+ 418... about 6 years old). The problem: twice now, the pump got stuck on running continuously. It's not...
  2. S

    Lime render, wrong paint

    Hi I'm wondering if someone could advise what my options are. 1930s detached house, solid brick walls, lime mortar and roughcast (or pebble-dash?) render. We have some damp internal patches in various places. Previous owners had it painted outside with non-breathable paint. In some areas, the...
  3. S

    ABV always flowing, Smart valves and overheating boiler

    Just in case anyone has some ideas to point me in the right direction! The system: Vaillant EcoTec 418 system boiler with unvented tank. S-plan (2 zone, CH and HW). Grundfos 3-speed pump (set to 2). Recently added smart valves (Drayton Wiser) to 5 out of 9 rads, so boiler load is reduced (all...
  4. S

    Drayton Wiser and Vaillant Boiler

    Hi I have a cpl of question, but I'm also posting as this might help others trying to get Drayton Wiser to work properly with Vaillant (or other boilers). Setup: ecotec plus 418, S plan, installing Drayton Wiser smart controls (currently 3 rad valves). Problem: the boiler is short-cycling...
  5. S

    Can wiring be changed to avoid bypass loop?

    Hi all quick question.... My system: Vaillant EcoTech 418, S-Plan system, 2 zones (HW unvented cylinder + CH). There is a short loop with auto bypass valve. System works fine but I am attempting to upgrade to smart controls (Drayton Wiser). The new controls seem to operate via short bursts of...
  6. S

    Different flow temperature for CH and HW

    Hi My setup: S plan, Unvented cylinder, Vaillant EcoTec 418 (all works fine). The boiler has 2 knobs to set the flow temperature (for heating and water), but one of them seems to do nothing. i.e. the flow temperature target is what I set for the central heating independently of what the system...
  7. S

    Wiring: removing RF receiver

    Hi I'm a newbie looking for some advice. My Setup: Vaillant 418 Ecotec, S plan system. Salus RT500RF receiver+stat and wired controller. I'm switching to smart controls (Drayton wiser). I replaced the wired controller and It's all working as long as the old RF stat is calling for heat, but I...
  8. S

    S-Plan with no Bypass

    Hi Great forum btw! I have a Vaillant EcoTech 418, S-Plan system, 2 zones (HW unvented cylinder + CH), installed 1 year ago. Standard 3 speed Grundfos pump. The system seems to work, but boiler periodically (say once a month) cuts out with error F72... "Flow and/or return NTC fault". I've now...
Back