  1. B

    Bentone Sterling 40 Oilfired Burner Cutting Out

    Burner cuts out. When I try to Reset, The burner fires for a short time. I have to reset six or seven times before fires. The Burner then runs for perhaps half an hour - presumeably until the correct watyer temperature is reqched. Then, I have to go through the whole process again and the...
  2. B

    Central Heater Burner Cutting Oyt

    Burner cuts out. When I try to Reset, The burner fires for a short time. I have to reset six or seven times before fires. The Burner then runs for perhaps half an hour - presumeably until the correct watyer temperature is reqched. Then, I have to go through the whole process again and the...
  3. B

    how to fit MCB onto Busbar

    Good Afternoon I have a 20 Amp Garo MCB How can I physically affix the MCB on to the Busbar? Has anyone got a leaflet showing info on the MCB Many thanks
  4. B

    Problems with porcelain polished tiles - tiles lifting and cracking

    Good afternoon, About 10 years ago, we had a new kitchen installed. My daughter had at this time purchased a new house and she had porcelain polished tiles installed in her kitchen on a cement floor. My wife wanted these tiles, and a coalition of other family members agreed. I was not too keen...
  5. B

    Immersion Heating Problem

    I'm in the process of replacing my old fuse board with a Consumer Unit. It is in the planning stage Recently, I found that the 20 amp fuse feeding the immersion heater was blown. I replaced the fuse with a new 20 amp. After a few days, this fuse also blew. When I removed the fuse, the body...
  6. B

    What size step ladder should I buy?

    Good Evening all I want to do some drilling at a height of approximately 2 metres. What size ladder should I buy. How far apart would the legs be at ground level? Many thanks Jimmy
  7. B

    What size step ladder should I buy?

    Hi I need to do some drilling at a height of over 2 metres. I want to buy a suitable step ladder for the job. Could anyone suggest a suitablr size. What would the the leg spread be at tha bottom. ANny suggestions would be appreciated
  8. B

    Gate Valve on domestic central heating tank

    Good afternoon. The gate valve on my oil tand is rather old. It accepts a 3?8 inch copper pipe. Will I have any problems connecting a 100mm copper pipe to the valve? If the pipe will not fit, how can I get around the problem? Any help would be gratefully received! Jimmy
  9. B

    Bentone Burner Fireup Problem

    I have a Bentone Burner Sterling 128 app. 13 years old. Recently. the burner has been very difficult to start in the morning ofter requiring 4 or 5 resets. I noticed that there was a leak in the oil feed to the burner. I replaced the oil filter, the fire valve and re-tightened the pipe...
  10. B

    Bentone Burner - Oil Pump Replacement

    I wished to replace the Oil Pump in my Bentone Sterling ST108 Burner. I studied a video produced by Danfoss outlining the steps to be taken in replacing their BFP 21 L3 Oil Pump. No problems except the video featured a different burner. I'm going insane in trying to figure how I can detach...
  11. B

    Oil Pump - Suitable Replacement

    Hello everybody. Is a Danfoss BFP 21 L3 pump a suitable replacement for a Danfoss BFP 11 L3 ? Information would be gratefully received
  12. B

    Bentone Burner - Sterling 40 not firing

    On startup, the burner would fire for a period of app. 10 second, and then cut out. It would attempt to restart and eventually cut out again. After about 3 resets, the burner would finally stabilise. The problem worsened. Finally, after resetting would again, there seemed to be a sudden...
  13. B

    Oil filter Replacement

    Good Evening, I wish to replace the oil filter on my central heating system. Could someone advise me if a 10mm copper pipe can be directly connected to the oil filter, or will I need another connector? Will I be able to connect the oil filter directly to the fire valve using 10mm copper pipe...
  14. B

    Joining Imperial Copper Piping to Metric

    Good Morning My house is fitted with imperial measurement piping. Only metric is now available My Question ======== Can I use a 10mm straight through connector to connect 3/8 inch pipe to 10mm Can I use a 10mm straight through solder connector to solder a 3/8 inch pipe to a 10mm Can I use a...
  15. B

    Indesit Dishwasher - Water Pressure Problems

    Good Morning. An Error Code is appearing indicating that the machine is not filling up within a set period. I have checked the mains water pressure. Meter reading is: 20 PSI (1.5 Bar) Is this water pressure adequate to enable the machine run properly? Any advice would be gratefully...
  16. B

    Drum Bearing Replacement Zanussi Washing Machine - Pooblem

    I am trying to replace the drum bearings - Have full instructions I have run into the a problem- I am trying to remove the pulley wheel from the Drun spindle. It is fastened with a countersunk hex headed M10 x 25 bolt. I cannot get the bolt to budge. I inserted an alan key into the hex head -...
  17. B

    Nexus 8 Alarm Panel - How to Reset Master User Code

    Good evening all, I have reset a Nexus 8 Alarm Panel which I installed myself. I have the Engineer Guide for the Panel and I have reprogrammed the unit. However, I have run into difficulty when trying to change the Master User Code. I have succeeded in changing the Engineer code from the...
  18. B

    Jigsaw Blade wear

    Good Evening. I have a Black and Decker Jigsaw. I fitted a brand new blade. I then used it to cut through two 4ft. lengths of 18mm chipboard. The blade was then totally worn out. Is this normal wear. The blade was a C.K type C. Any advice would be much appreciated
  19. B

    Nexus 8 Remote Keypad Problem

    Keypad Dead Alarm Panel appears OK. Alarm sounds when a Panic Button is pressed. I would be grateful for any ideas. Has anyone any ideas where a Remote Keypad could be purchased? Many Thanks
Back