  1. M

    termination tightness

    Well it's not like tightening your car wheel nuts. The best I can think off (although I've done it 1000's of times) is, slowly tighten until you feel resistance then give another 1/8 turn. If you can pull the cable out it's obviously too loose. Its not an exact science.
  2. M

    Consumer Unit Replacement

    You're more of a spark than the crook you employed. All experienced straightforward electricians always test before changing a cu, this so they can repair faults that would prevent the new cu operating. The ones that don't test before are crooks and should be thrown out of the industry. You...
  3. M

    Request for help in removing ceiling roses & consealling connectors when fitting room spots

    That could be a problem. In many flats the ceiling is part of the building fire protection system, and therefore it is not permissable to make holes in the ceilings. You should check with your landlord/deeds as to what is permissable. You could end up in serious trouble if you adversly effect...
  4. M

    2 gang light switch

    Yep, that's the way to do it.
  5. M

    Consumer Unit Replacement

    That's similar to what i would have done, removing the back box of the old board was a totally stupid thing to do. But we are where we are! I would extend the remaining conduits using https://www.edwardes.co.uk/en/categories/adaptors-knock-on-steel. Your spark could then fit a box/boxes large...
  6. M

    Broken GU10 Light bulb in flush fitting

    Make absolutely sure power is OFF. Use needle nose pliers
  7. M

    Remove a pendant and ceiling pull switch

    Happy days are here again.
  8. M

    Upgrade to 3 phase

    But I have never mentioned #2 sketch, only ficticious #3 sketch You see when you said "I have worked in some big control panels where neutral is not even brought into the enclosure" that meant to me that a tp&n supply was taken to the enclosure, but the neutral was not taken into the enclosure...
  9. M

    Kitchen electrics - illuminated switches question

    And his cryptic nonsense that will one day kill someone.
  10. M

    Upgrade to 3 phase

    Makes sense to me, but you said "where neutral is not even brought into the enclosure", what does that mean?
  11. M

    Kitchen electrics - illuminated switches question

    deleted in view of the usual insults, why don't you people go and find a 12 year old to bully, you might succeed in getting them to commit suicide, that would be proud moment for you all.
  12. M

    Upgrade to 3 phase

    My mistake, my education was complete, and I was right you described a fictitious circuit that has never existed because it would never work. Because it is not required. So what do they do with it, just leave it hanging around?
  13. M

    Getting new electrics rechecked?

    If you didn't, demand it now, it is your right, you have paid for it, and without it your property is devalued.
  14. M

    Main Trip Switch Tripped, All Power lost, electric cooker element.

    No he won't be an engineer or a qualified electrician, he will be a spare part fitter. It seems you have a dedicated cooker circuit which is not being used, and your cooker is connected "somehow" through a plug and socket. What are the cooker details? and can you post a pic of your consumer...
  15. M

    Upgrade to 3 phase

    Oh my education is incomplete, where could I expect to find that arrangement?
  16. M

    Upgrade to 3 phase

    Yes, didn't realise you were talking about a ficticious circuit.
  17. M

    Upgrade to 3 phase

    what? quite right, well done.
  18. M

    Upgrade to 3 phase

    hahaha, once again none of them know what the other is talking about, the waffle has got too deep. And drawing no3 is nonsense, because it is a ficticious circuit that would never be used, any sp load will trip the rcd EDit - Didn't realise the drawing was ficticious
  19. M

    Non-standard power strips sought

    grammar. Thats grammar, not grandma.