  1. K

    Concrete lintel help

    I'm having some alteration work done in conservatory which includes an opening from adjoining room into the conservatory. There was original opening approx 1.2m which will now be 2.5m. We're in process of putting concrete lintels in. Both outer and inner skin. On inner skin the new 3m concrete...
  2. K

    2 faulty motorised valves?

    Hello, I have an issue with rads getting hot when turning water on only. I have 2x 2 port motorised valves and running some tests. I've took the heads off both valves. Rad motor seems to turn when i switch rads on Water motor seems to make an off clicking noise from motor so i suspect this...
  3. K

    Leak on unvented pressurised heating system

    Hello, I have been losing pressure on my system for some time and have gone through a process of elimination over last few months and completed the following: Boiler Service and health checks Replaced a PRV that was causing a tundish overflow Pressure vessel by water tank replacement as it...
  4. K

    Unvented heating system losing pressure

    Hello I have a closed unvented heating system that loses pressure very regularly. I am having to top-up the system via the filling loop every 2 to 3 days to 1 bar, then it's down to zero when I top-up again. The tundish on my system was discharging recently and a pressure valve was replaced...
  5. K

    Tundish discharging water constantly

    Hello, On my heating system, the tundish by the hot water tank is constantly discharging. I did have a valve replaced about 2 years ago, i believe it was a valve at the PRV. Would it be likely that this valve has gone again? Is it common that these valves can get faulty every couple years...
  6. K

    Outside garden lights connection query

    Hi, I'm planning to install some garden festoon lights. They have about 20 bulbs and are 240v. There is an existing light outside and I was hoping to remove that and connect into the 240v connection that is there. The existing outside light is a spur fed by a light switch on the 6amp lighting...
  7. K

    Faulty Pressure Valve? Tundish constantly discharging water.

    Hello Any advice would be very much welcome here. Noticed my tundish is constantly discharging water. I don't think there is too much pressure in the water system as that reads just over 1 bar, but i could try releasing some pressure here? Likely there is a faulty valve but there seems a few...
  8. K

    Is this my filling loop?

    Hi, I need to drain my system after running cleaning fluid into the system a few weeks ago. I have a Greenstar 24i boiler that has no filling loop, so I need to find where the mains water is getting into the system. Looking at the picture that I've attached appears to be the filling loop. Do I...
  9. K

    Suspect Motorised Valve on Central Heating

    Hi, When turning my hot water on, i notice the radiators also get heat. I've checked my system and i believe it is an S Plan system as i have 2 2-port motorised valves, one for water and one for heat. When my programmer calls for heat or water i can hear the noise from the motors and the...
  10. K

    Radiator replacement needed?

    Hello all, I have a radiator in the house that is hot at the top and cold at bottom. Seems most likely cause is sludge or dirt in the radiator so i've taken the radiator off and hosed it through which a lot of dirt came out. I've put it back on but still i have the same issue, is it likely...
  11. K

    Slow water flow in pressurised heating system since water meter install

    Hi all, I've just had a water meter installed and now the water flow in the house is very slow, seems to be affecting both cold and hot. The heating system is pressurised and i have the Zilmet Ultra-pro vessel. I'm wondering if there was some pre-cautionary measure that i should've taken...
  12. K

    Worcester Boiler & Hive Dual Channel Wiring help

    Hello all. My current setup is Worcester Greenstar 24i Boiler and hot water cylinder. The boiler programmer/thermostat is the wireless Salus RT500F. I'm looking to replace the Salus with a Hive dual channel and wanted to understand how the wires are connected back to the boiler. I've...