Search results

  1. H

    Light Pendant to LED wiring

    Hi I took a light pendant down to fit an LED fitting. There are 2 Cables coming into the pendant. Below is how the pendant was wired. The Red out of cable 1 went to Blue and the Black out of cable 2 went to Brown. Now, from Cable 1 black was cut, and Cable 2 Red was cut. They had been cut at...
  2. H

    Fridge Freezer, Freezer and Washer. Garage electrics

    The fuse box is located in the garage which is integral to the house. This is where a fridge freezer, under counter freezer and washed are located. The garage power/sockets has its own fuse (32A) there are 2 double sockets on the opposite side of the garage and a double socket where these...
  3. H

    Tree/Shrub identification

    Evening We have conifers surrounding our garden but in between is a tree/shrub. The branches Off this tree all intertwine together and some grown on the conifer trunk and wrap round/,circle it. Attached is some pictures Thanks
  4. H

    Tree Identification

    Evening Would somebody be able to identify this tree from the pictures? It dropped some stuff? (buds/fluff?) a month or so ago then leaves appeared. If that helps?
  5. H

    Thermostatic Shower

    I have fitted a new Mira Thermostatic Atom shower (large fixed head with diverter). The temperature is just warm, not HOT. I have adjusted the temperature to max behind the temperature handle as the instructions. Every other Hot outlet in the house gets very Hot. The pressure everywhere...
  6. H

    Kitchen electrics - 2 ovens and more

    We are currently redoing our kitchen. I have got an electrician in so I am not doing any of the following work. It's just to check really as looking online seems it's not correct. Layout is: Double socket number 1 loops out and feeds double socket number 2, loops onto hob socket,this spurs to a...
  7. H

    Mixer tap making cold pipe warm

    Just fitted a new basin with a Grohe mixer tap. The tap has 2 flexis pre-installed which I have connected to hot and other to cold. Our system is a Worcester 28i Junior boiler, cold tank still present in loft feeding all cold taps in Bungalow (except Kitchen). No hot water tank. Hot water...
  8. H

    Do I need extra CCTV equipment?

    Looking at the CCTV the house has. I don't think it's anything high end. We don't currently have internet access at the house but we will do on the near future. We will want to be able view the cameras over the internet/via an app. So of I need to upgrade anything I will do beforehand. Already...
  9. H

    Open shower door

    I've got a shower tray to fit, a 1000 X 800 offset quadrant. It is only in a small ensuite (1800x1550) and we were thinking of just having glass on the 2 sides and having the quadrant part open. Shower tray will be raised off the floor on a plinth and a rainfall shower head. Do you think much...
  10. H

    Shower Tray

    I'm replacing all the ensuite in the en suite. My plan in order: No more ply Lay shower tray (on floor direct or riser) Tank Tile/ shower boards Floor Fit toilet/sink Just looking at what will be best for the shower tray. It will be a stone resin shower tray, on top of no more ply (to cover the...
  11. H

    2 Downlights

    Looking at changing the wiring to 2 Downlights and get rid of a junction box and be able to control both of each switch. The first image is of what is currently present. The second is what I'm looking to do. Currently 1 switch does only 1 light so I'm looking to control both lights off each...
  12. H

    Alarm panel Replacement?

    Good Evening I have inherited a Scantronic 9448+ plus alarm system at the new house. When I try to set the alarm, Zone 2 would light up. When the alarm was NOT set the sensors in Zone 2 would flash. These are shock sensors. I replaced the sensors in Zone 2 but as I was changing the last one...
Back
Top