Search results

  1. C

    Corgi taking the P?

    I have been corgi registered since before it was compulsory and have always supported the almighty corgi. But even I am now starting to get hacked off. I recently had one of their supprise (sneaky) inspections. The one thing that they inspector picked up was a lack of lagging on the condense...
  2. C

    Sanishower

    Is there any other alternative to this product? My new shower outlet is lower than the soil pipe. If not I'll get on of these. TY.
  3. C

    Tiled floor

    I've just created a new shower room down stairs. The floor is green chip board. With a marley floor drain in it. I have covered the floor with floor tiles and sealed the wall tiles to the floor with a good quality silicon. Shower worked great, stuart turner 4 bar pump to 2 ceiling roses and 4...
  4. C

    New control for OAP

    Anyone have any ideas on a new heating hot water rcontroller. Something simple and easy to read as the old dear is half blind and has oldtimers too. She's finding it hard to read the randal 102.
  5. C

    A good BG Job.

    A couple of pics of an installation by BG. We were called to carry out a powerflush. Elbow off top of cylinder pipe bent down and gate valve. Nice. Needless to say we altered the pipe to rise instead of fall and removed the gate valve. Quality assured???
  6. C

    Worcester 40CDi

    Installed a nice new 40CDi on November the 23rd last year, I know the date because it's me b'day. Yesterday customer calls to say it's displaying temp in boiler then alternating to SE. Called WB they inform me that SE is code for service. The boiler is only 6 moths old. Even if it's been on 24...
  7. C

    Alpha CB28

    I've been to look at one today and the red light flashes then the yellow light flashes. This is the Primary Pressure Switch at fault, as it has system pressure. Does anyone have a schematic of one or a link to one so I can easily locate it? As the book of words is not on site. Many thanks.
  8. C

    CORGI PLUMBING

    Am I being cynical? Or is the CORGI plumbing registration scheme just another money making exersice? Did I read the form right? Is it really another £300! Even Dick Turpin wore a mask. :cry: I've been a Corgi member since before it was compolsary and have supported them. But I'm begining to...
  9. C

    Magnetic filters

    Quick show of hands please. Magnaclean or Fernox boiler buddy? I've fitted a few magnacleans and they are great. the Fernox one looks better but is it less easy to dissasemble? Looks it.
  10. C

    Commisioning boilers.

    What are peoples views on commisioning other peoples installations. I've been asked to do it and they want it certified. Trouble is the work looks crap. I don't want CORGi (nazi) comming down on me. I don't think it's worth it at any cost. What do U guys think? :roll:
  11. C

    Vokera linea 24

    Hot water keeps running cold half way through a shower. Not every time. went there today and it was all ok. anybody any ideas what might be causing an intermittant fault? I was thinking temp' sensor. Not had much/anything to do with vokera's before. Boiler is apprx 5years old.
  12. C

    Worcester 24CBi

    Boiler is 2.5 years old. Fitted by another installer which the customer will not have in the house. Boiler is leaking from the right hand side of the heat exchanger. I took the boiler apart and replaced the O-rings, flushed out the magnatite from the exchanger and refitted. This lasted 3 weeks...
Back