    Vaulted ceiling problem!

    Hi, made the mistake of not under boarding my rafters with foil insulation or adding a polythene VCL. I have 150mm foiled back insulation in between rafters only and 15mm wallboard screwed to the rafters, now the weather has turned I’m getting isolated condensation spotting (which is really...
  2. M

    Vcl type paint

    Hi all, got a problem and missed a Vcl in my lean too roof, was hoping there was a proven VCL type paint than overboarding it. thanks
  3. M

    Drafty spot lights causing issues... maybe!!

    Morning all, I noticed last night when looking up at my ceiling in my lean to extension as I have some condensation water spots showing on my ceiling. the spot lights I installed are bringing in quite a lot of cold air into the kitchen 8nr over a 8.7mtr length. Would this be contributing to my...
  4. M

    Does this eaves detail look right

    Hi all, im having a right nightmare with our low pitch profile eaves detail (roof 14.7 degree) From the photo does this look ok?
  5. M

    Weird shadow mark

    Hi all, We had our kitchen tiles roughly 10 days ago with white 600 x 600 porcelain tiles, we have Electric UFH, I wait the 7 days before turning it on. I notice last night there we have some form of dark shadows appearing on the tiles. It can’t be a leak as we have no pipework in the floor...
  6. M

    Pitched roof

    I’ve recently had an extension built, it has a pitched roof (vaulted ceiling internally) we have a 14.8 degree roof with a tile that can go down to 12.5 degrees (Marley melodie) we have gone for a 175mm x 50mm TR26 engineered timber rafter (Fully designed roof) with 150mm PIR insulation in...
  7. M

    Cable thickness

    Hi all, I’m currently doing a new single storey extension which will become a kitchen. We have a 6mm twin and earth cable from the board (on its own 32amp) would this provide the necessary power for the following oven - 3.6 Kw Induction hob 7.4 Kw Combo oven - 3.6kw can the oven and combi...
  8. M

    Water over shooting rear gutter on extension

    Hi, we have recently had a rear extension built, the house roof guttering falls on to this roof. When the rain is heavy, we are finding the water over shooting the gutter!! we have a rolled tile due to the low pitch, which basically makes the matter worse. I need something that will spread...
  9. M

    Low Level Pitch on single roof with roof lights - help

    Hi All, i appreciate this topic has come up many times! I'm starting an extension on the rear of my property, I'm going to either use a the Marley Melodie or Foritcrete Centrium, my pitch currently at a max of 14 degrees maybe more like 13.8. i have reviewed the low level flashing which fakro...
  10. M

    Noisy radiator’s (Very strange as only three)

    hi all, I have recently had a new Combi boiler installed a ideal logic 30KW Everything is ok with the exception of the three radiator’s upstairs (Landing, back bedroom and front bedroom) When the heating is on I can hear a noise, which sounds like running water / the boiler noise coming...