Search results

  1. D

    Zanaz\Better Bathrooms WC Fixing Frame O-Ring Issue

    Hi There, So we are having this fixing frame installed, and it seems to be missing an o-ring as per the picture. The White Pipe is the verticle Flush Pipe (18 in the diagram), the external diameter of that is 2 inches. The horizontal flush pipe sits inside that (5 in the diagram). The groove...
  2. D

    Towel Radiator Bleed Valve Query

    Hey, So I have this kind of Tower Rad installed: https://victoriaplum.com/product/the-heating-co-santa-fe-traditional-radiator-952-x-659 As per the pictures attached it doesn't use the standard 1/2” BSP valve size, what is it using? I am guessing it is a 1/4? Cheers
  3. D

    Glass Shower install

    I'm going through the install guide for this Victoria Plumb glass shower screen and I don't quite understand what it means in the attached picture. 0~15mm gap, does it mean the screen should not butt up right into the mounting frame and there should be 0~15mm gap? The reason I ask this is that...
  4. D

    15mm tap end tails

    Hey everyone, I bought a few packs of these as they are supposed to be good for connecting flexible pipes to standard isolation valves. For the life of me I can't get the olive to tighten enough to create a water tight seal. I tighten it as was as I can and I've even tried putting some ptfe...
  5. D

    WC3 Stuart Turner Macerator query

    So I have been building out an en-suite and I've done the waste pipework for the basins and the shower. To get the WC to hook up to the WC3 I need a straight connector, not very long but the standard built-in connector isn't enough. I've tried a McAlpine one: McAlpine Macfit WC Straight...
  6. D

    Replacing plasterboard and boarding to existing skim coat and joints

    Hey Everyone, So I have skimmed plasterboard before and can do that pretty well. But I had a partition put up and that was boarded and skimmed. I have had to rip a section out this weekend as I wanted to lay some pipework into the wall. As you can see from the attached picture I just ripped...
  7. D

    32mm solvent weld to plastic waste stack for macerator

    Hey Everyone, I have been researching this and I am a bit confused on how to terminate the macerator waste, into a normal plastic soil stack I have in my loft. I fully understand that the waste has to be solvent weld because of the pressure, so how do I terminate it correctly to the plastic...
  8. D

    En Suite Queries

    Hey Everyone, So I am doing an ensuite in my house. The walls have bonding (old) and have been skimmed (6 months ago). Looking back that probably wasn't the best way to go. My original plan was to use No More Ply, screw wooden battens into the wall for the shower area and screw the No more...
  9. D

    Macerator Install Query

    Hey Everyone, So I have been reading these forums for a while as I am renovating a house. We are putting in an ensuite, and because the waste pipe is at the back of the house and the ensuite is at the front of the house, we have decided to get a macerator. I've done a bunch of reading but I...
  10. D

    Baxi Megaflo 28 System ErP General Query/Help

    Hi! So I have just moved into a new house and it has the above boiler fitted and I am trying to understand it as best as possible. The control is set to water and central heating, Normally there is a temperature control for the central heating and then one for the water, but this is combined...
Back