Search results

  1. S

    Sylfire coolfit GU10 Bulbs - Replace With LED

    Hi, I've currently have a GU10 mains downlight in my porch. The installation instructions say it requires "forward heat aliminim reflector" lamps and not to use dichroic lamps. Would it be ok to use an GU10 LED bulb in this fitting ? as I have a few left over from putting them in my...
  2. S

    Loft boarding - Celotex

    Hi, I'm just about to start boarding my loft as I need some extra storage space. But need some advise before I start. At present I have 100mm rockwool between the joists. I have been given some Celotex 100mm PIR boards that my dad had left over. I am planning on putting these...
  3. S

    Baxi Combi 133HE - Baxi Intellistat (Thermostat)

    Hi, My nan currently has a Baxi Combi 133HE boiler with a Baxi Intellistat (Thermostat). The heating is failing to start whatever you set the thermostat temperature to. The hot water is working fine, so im guessing the Intellistat is faulty. Is there anything I can do to temporally get...
  4. S

    Replacing laminate with carpet. Underlay?

    Hi, At present in the living room we have a laminate floor that has (quickstep combifloor underlay with DPM), the missus wants to replace this with carpet so our 6 month old can crawl about. What I need to know is what do I do with the underlay. I know you cannot use carpet underlay...
  5. S

    Fitting Electric Fire – Cable Size

    Hi, Been in our house for about a year now, and this is the first time I’ve had a look at the electrics ! I recently purchased an electric fire with the intension of connecting it to one of the sockets in the living room (That isn't already feeding any spurs) via a 13A FCU. I was...
  6. S

    Closing Fireplace - Flue Liner Need Removing or Not

    Hi, I have recently had my old Back boiler removed and replaced with a new Combi Boiler which is located elsewhere. I intend to brick up the opening in the chimney and include an airbrick for ventilation Before I brick it up, as you can see from the picture below there is still a flue...
  7. S

    Glow-worm Fuelsaver 35 F - pilot light keeps going out!

    Hi, I have a Glow-worm Fuelsaver 35F boiler, which fires up then goes out after about 1 min. It does relight after a while but then goes out again after a further minute. It seems like it is overheating or thinks it is so cuts out. I have checked the pump and im fairly sure its ok...
  8. S

    Danfoss Randall 103 timeswitch replacement

    Hi, I currently have a Danfoss-Randall 103 mechanical timeswitch, & would like to replace it with an electronic model. Could anyone tell me if there are any other timeswitches, other than the Randall 103E5 or 103E7 models (to expensive), that can replace the 103 without altering the...