Search results

  1. N

    Outside hose fitting

    I've bought an outside hose kit, it's exactly what it said it would be ( not suitable for pressure washers) I imagine this is due to the self cutting tap that has the same pressure as my late 40s bladder, I've bought a 15 mm Tee compression to replace it, however I can't find a 3/4 male (...
  2. N

    Reconditioned pcb, now what!

    I've just bought a reconditioned pcb for my ferroli 901, I've had one in the past from the same company no problems, when I plugged this one in the leds just come on very faintly and go off, the clock works and the pump runs but nothing else, is this likely to be a faulty board, all wires...
  3. N

    Possible external expansion tank error

    I've just fitted an external expansion vessel to my ferroli as the internal one was passing a lot of water, it's created another problem, it all went well, fitted to return pipe ( i double checked) joint eventually stopped leaking but then.... When I fire up the boiler in burns for about...
  4. N

    can I replace expansion vessel at rear of boiler.

    Evening , The expansion vessel is ****ing water , wont hold pressure , its one of those pain in the backside ones that are round like a steering wheel and on the back of a ferroli 901 , I can see how it all plumbs in and can buy a new one for £50 , however can this be removed without taking...
  5. N

    Should water shoot out of auto air valve?

    I've a combi boiler with an auto air valve, the cap is missing, it's been missing for years, when I press the valve down water shoots out, otherwise it doesnt leak at all, I'm assuming this is faulty, I'd appreciate any advice, I can change it if needed for about £20, it's not in the...
  6. N

    Old problem fixed ferroli 901 , new problem turns up

    Ok, I know it needs chucking but I'm currently skint so I'm trying to drag it out. My Ferroli 901 used to short cycle, now I don't know if I misunderstood short cycling but the water / heating used to turn off because the Thermistors were faulty, hot, cold, hot again. I always thought...
  7. N

    Electric boiler query , also reviews would be appreciated

    My gas boiler is weeks away from the scrapheap , I have a few questions regarding electric boilers , I have a 1 bathroom , 2 bed terrace . according to the info I have read from a size point of view this is suitable. If I get a gas engineer to remove the old one , could I potentially install...
  8. N

    Adding a socket via a junction box clarification .

    I've added spurs before however not via a junction box, all cables currently run up into a one level void ceiling space which I can access but not get into because it's narrow, it a galley kitchen but all the plugs are at one end with electric wires running to rear which is bathroom...
  9. N

    QUITE SPECIFIC SHORT CYCLING BOILER QUERY , FERROLI OPTIMAX

    Good morning , hope you all had a great Christmas , Ive got a optima 901 boiler combi which is short cycling , heating is ok , its the hot water that runs cold, hot, cold. its possibly the heat exchanger , however the boilers too old to replace this part , it wouldnt be cost effective. Its...
  10. N

    6011 weld rods availability.

    Good morning , can anyone tell me where I can buy 6011 weld rods either online or in the Birmingham area , everywhere seems to sell 6013 but not 6011. is there another name for 6011 as searches mainly bring back American suppliers , I am currently repairing an old 1970s bumper , the second hand...
  11. N

    intermittent brown water from hot tap

    This morning I discovered that there was brown water coming from the hot tap only (all hot taps) , looks like the sort of thing you get when road works have taken place , however not the case as only the hot tap effected, this is obviously something to do with the boiler. Everything I have found...
  12. N

    optima 901 losing pressure overnight

    I know it needs scrapping , however my finances currently disagree with me regarding that decision. Currently boiler doesnt turn on in morning, this is because pressure has dropped to 1.0 , as soon as I top it up using the loop to 1.5 it kicks in , PRV and pipes all seem fine , cannot locate...
  13. N

    Washing machine broken "spider" can it be fixed

    My washing machine was banging so I assumed it was the bearing, I spent 2 hours getting into the guts of it so now it's just an empty metal box and bits, I think I remember where everything goes, it wasnt the bearings, the "spider " at the back cracked, the picture looks like it's really...
  14. N

    Very hot combi pump, question re advice given

    The pump seems to be moving the water, however Pump is getting very hot indeed, I've removed the small metal disk and it does spin freely and doesn't make a noise, please look at attached advice, is this suggesting that I turn boiler back on with the metal disc removed? Won't that throw...
  15. N

    Draining down combi system

    I own a terraced house, the boiler is upstairs, the one Rad with a drain fitting is a step up from the others downstairs so im a bit concerned that the 3 others downstairs won't empty. Can I turn off gas to boiler, leave the cold water flow to the boiler on and attach a hose to the Rad drain...
  16. N

    FERROLI 901 PUMP GETTING HOT

    I have an issue with my ferroli 901 short cycling , it fires up for approx 3 minutes , then shuts down , radiators seem fine, however water runs hot/warm , im assuming this is due to short cycling. i have changed the thermos on the copper pipes and the direct flow meter , ive been told its...
  17. N

    BOILER PUMP QUERY

    Recently I have been getting full CH however hot water runs for a while , then goes warm then fires up again then gets hot for a few minutes and then does the same , ferroli boiler optima 901 , its been suggested that its the heat exchanger , however this morning Ive noticed that the boiler...
  18. N

    Intermittent hot water Optima 901

    Ongoing issues with boiler , I require a few answers to a few questions please , it would be great help , going through a process of elimination. Heating seems ok , however water gets hot , runs hot for a few minutes then goes cold , then starts to get hot again . I've changed the thermo on...
  19. N

    Ferroli Optima 901 hot water issue

    Evening , I appreciate that there are a number of similar issues on this forum and others , however none of these have helped so I'm asking for my specific issue. My boiler is 20 years old , only previous issues have been with PCB which Ive replaced a number of years back My CH is fine ...
  20. N

    Ceiling rose fitting problems

    My wife has purchased a lightweight ceiling rose (polystyrene) , she's the designer and I'm the magician that's going to make it all happen ( sigh!) It's move or less flat , I've done one before with no issues. I removed the light fitting and there's a lot of wires up there as well as a hook...
Back