’m looking to insulate a vertical wall onto a cold roof in London. The wall, from inside to out, is paint / presumably plaster / sheet timber (unsure whether OSB / plywood / something else) and a few supporting battens / cold roof.
I guess the key question is whether a VCL is needed on the warm...
Hi
I'm keen to insulate a loft with unusual construction (see below). I'm hoping that can be the usual "roll out some mineral wool" to a depth of 300mm (and raise any boarding above that by at least 50mm). But am weary of condensation risks (all the more so as this is a timber frame, timber clad...
Hi
I’m hoping to improve the loft insulation of a cold roof of a large (c. 350m2) wood clad, timber frame bungalow that is currently poorly insulated and struggles with heat retention. It is currently largely single glazed (I’m working on secondary glazing with Magnetglaze Extreme Pro and 4-6mm...
Hi,
I have a c. 9x8m loft in a 1860 ish Victorian house which I'd like to insulate now*. As you can see from the below, it's barely insulated, but is currently "cold roof" construction.
1) It's possible I may ultimately end up doing a loft conversion (in maybe 5+ years). It'd be preferable...
Hi
I’m hoping to improve the loft insulation of a cold roof of a large wood clad, timber frame bungalow that is currently poorly insulated and struggles with heat retention. It is currently largely single glazed (I’m working on secondary glazing with Magnetglaze Extreme Pro and 4-6mm Perspex)...
We have a large (c. 5.33m x 1.68m – measured internally, so I’m guessing nearer 5.5m x 1.8 or more externally) singled glazed angled roof light. It appears to be made from two sheets of glass.
1) The seals are failing and need replacing/repairing. The roof material is made from fibreglass...
Hi,
I'm after some replacement casement windows and sliding patio doors in a timber frame/wood clad house. White inside, rosewood (or similar RAL colour) outside. Any thoughts on what material is best, and why? Seems to be a fair it of conflicting advice (much of it from interested parties!)...
Hi,
I need to replace a single glazed (security glass) 2 pane external sliding door, c. 2380 mm wide / 2082mm high. Near Crystal Palace.
The current one is hardwood with two single panes of security glass, but is in a poor state and would need significant rebuilding (I'm open to that, but can't...
Hi,
Our AEG 5 burner gas hob blows its fuse (the one in its plug) and trips the RCD and MCD. The odd thing (to me, at least) is that this happens when it's not being used - e.g. it happened whilst we were on holiday. Replacing the fuse (3A) provides a temporary fix for a limited interval...