Search results

  1. T

    Double Built in Oven

    Just one point.... The instruction manual says to use 2.5mm T&E !
  2. T

    Double Built in Oven

    Hi Guys I think that it will be notifiable as I am replacing an old cable that hasn't been used for years so that I can go back to electric from gas. Just needed to clarify.
  3. T

    Double Built in Oven

    Thanks for the rapid replies guys. Is it permissible for me to do the work and then have it inspected and certificated to part p
  4. T

    Double Built in Oven

    Hello all... Can anyone please tell me if 6mm Twin & Earth is suitable to run a 4.12KW Baumatic Double Oven and what mcb I should use at the CU. Thanks
  5. T

    Gloworm Boiler wiring

    I'll definately admit that until I unravelled all the wiring I was confused and could'nt see everything. Now on the other hand it all seems to be a lot clearer (I hope). S/L should be the call for heat from the cyl stat, and P/L should be the connection currently tied in with the pump live. If...
  6. T

    Gloworm Boiler wiring

    My existing setup is a mish mash of connector blocks so thats why I bought a wiring centre. The new pack is a Drayton Sim-p-l Fit, It consists of a Tempus 7 programmer, wiring centre, pre-wired cyl stat, pre-wired drayton 3 way motorised valve and a room stat. The motorised valve and the cy...
  7. T

    Gloworm Boiler wiring

    Here we go... Yellow- cylinder stat Green/Yellow- Earth Blue- Neutral Black- Live (linked to central heating pump) Red- Live (from timer/programmer) Any ideas how that translates to L E N S/L P/L (i know E is earth) Cheers Rick
  8. T

    Gloworm Boiler wiring

    Hello again.... things are looking a little clearer now, the fuelsaver DOES have overrun and I have 5 not 4 cables running from it (red blue black grn/ylw and yellow) now I just have to work out what goes where. Are these wire colours industry standard Rick
  9. T

    Gloworm Boiler wiring

    I have studied the wiring diagram on the casing and it does show boiler overrun, but I am wondering why I've only got the one extra wire when I should have 2 (s/l & p/l). What could happen if I connected the live. neutral and earth to the wiring centre and left the yellow disconnected ? Rick
  10. T

    Gloworm Boiler wiring

    Thank you for your prompt replies... I can understand that the yellow from the boiler could be a call for heat, but there is no option on the wiring centre (unless it goes to the s/l on the boiler section). I have also tried to find the manual online but as yet cannot find one, so I don't know...
  11. T

    Gloworm Boiler wiring

    Hi...This is my first post so....Hello I have a Glow-worm Fuelsaver mk2 and have just purchased a wiring centre to tidy up the mess I currently have. This is the problem, the circuit board asks for live neutral and earth for the boiler, which is fine, but the boiler also has a yellow lead and...