  1. D

    Bosch Classixx 1200 (WAE24364) blowing heating elements.

    Hi, I have the above machine which has just blown its second element this year. The OE part lasted 3 years, the 1st pattern replacement lasted about 5 months and the second (pattern) has failed after 3 months. Is it just a case of coughing up £50 for a genuine Bosch element or is there some...
  2. D

    Triton Dew shower problem.

    Hello all, This shower has been fitted for about 3 years and until recently has been faultless. In the past few weeks it will start to run colder after a couple of minutes of operation. If you turn it off and then on again, it stays hot for another couple of minutes. The temperature control...
  3. D

    Potterton Promax 24HE leaking water, LHS of burner tray.

    As per title, there's a slight drip of water from the LHS rear of the burner tray. Only spotted it after the boiler started showing symptoms of either a faulty sensing electrode or blocked condensate trap (5 ignition cycles then lockout). Unplugging the trap sensor cured it, but then I noticed...
  4. D

    Banging pipes - blocked separator?

    Hello all, Our CH has recently started making quite voilent banging noises from the boiler/pump/valve pipework. It only seems to do it when the system is getting up to full temperature but there is sometimes also a single big bang as soon as the CH valve closes. It's an open S plan with std...
  5. D

    Potterton Promax 24HE keeps eating door seals

    Hello, My Potterton Promax 24HE is going through combustion box door seals like they're going out of fashion! I've just had to replace them again having replaced them just after Christmas. I'm very careful to make sure that the bolts are torqued down properly - this was after I had to replace...
  6. D

    Combustion box seal - Potterton Promax 24HE

    Hi, Does anyone know the part number for the combustion box door seal for the Potterton Promax 24HE? It's not listed in the short parts list. Thanks.
  7. D

    Frost stat wiring question

    Please reassure me that I'm not going crackers!! I'm almost certain that the frost stat circuit on our CH system isn't wired correctly. The frost stat is a Drayton RTS3 (or British Gas FS1 if you prefer), the pipe stat is also Drayton but I can't see a part ID on it. The frost stat backplate...
  8. D

    Moaning CH system

    Morning all, Our CH/HW system has recently started 'moaning'. It's quite an eerie moaning rather than a screeching or grinding noise. It seems to be worst after the system has been on for 15-20 minutes from cold. When it first started (just before Christmas) it was for 30 seconds or so and...
  9. D

    Long post and questions!!! (sorry)

    Hello all, I've recently moved into a house which has an old style 6 way fusebox, circuits arranged thus: 40A Cooker. 6A CH pump/boiler/controls 30A Sockets (study, hall, beds 1 & 2) 30A Sockets (lounge/diner, kitchen, utility, beds 3 & 4) Single socket in garage is also spurred off...
  10. D

    Hot water cylinder getting too hot

    Hello, We're having a new problem with our DHW getting too hot. It's a pumped system with 2 zone valves controlling CH and HW seperately. Potterton Promax 24 boiler. With the stat on the cylinder set to 55 degrees, it's possible to turn it to about 75 degrees where you can hear it click...
  11. D

    Potterton Promax 24HE problem - please help!

    Hello, We've recently moved into a new (old) house with a CH system fitted by BG approx 4 years ago. We've had issues with it since we moved in, namely - 1)Radiators not getting hot in some rooms, with others getting to about the temperature of the sun(!). 2)The boiler would cut out (or...
  12. D

    Advice please on boiler fan unit - Ideal Classic SE15

    I'm hoping someone can help me with this: Is it possible to remove just the blower unit from the boiler without too much hassle? I want to be able to get at the lower bearing in the fan assembly but I need to get at the underside of the blower so I can get the impeller off the motor shaft so I...
  13. D

    Quick question Re equipotential bonding

    Hello, When we had our consumer unit replaced a couple of years ago, the electrician bonded all the pipework together in the airing cupboard. As they are bonded there, do I need additional bonding in the bathroom? (which I'm currently installing). No additional pipes have been added, just...
  14. D

    Ideal Standard Conceala II cistern doesn't want to flush.

    I'm having a little problem with a new install of one of these toilet cisterns. I've got it all connected and the low capacity flush works fine. One firm push = flush. :) The problem is with the high capacity flush, it needs to be pumped at least three times before it will flow. I've...
  15. D

    Synchron motor replacement

    Hi all, Hopefully this is a nice simple question with a nice simple answer! I need to replace the motor in my Honeywell diverter valve (3 port - can't see a model number on the valve, it's probably about 20 years old though!). It is currently fitted with a honeywell 4000-2737-001 motor...