  1. R

    problem with a screed floor

    ive layed a screed floor in my bathroom at a depth of 25 mm as per building plans , its bean layed for a month and is cracking badly and i have some doubts if it is sticking to concrete below , concrete is 5 inches thick and was layed 3 months ago . i did not use any sealer on concrete on...
  2. R

    one light controlled from 3 swiches - possible ??????

    is it possible to control one light from 3 light switches ???
  3. R

    hot water tank

    im looking to replace my hot water tank and relocate it , at the moment i have a 65 litre tank in bedroom approx 25 meters from nearest tap i want to move it to bathroom and reduce it size as im removing bath and fitting a large shower cubicle with electric shower . idealy im looking for a tank...
  4. R

    mk circuit breakers

    ive fitted my new consumer unit , mk sentry split load board . i require a 63 A mcb for heating supply , mk site only shows them up to 50 A . does anybody know of another brand which is compatable with this board ???
  5. R

    new consumer unit advice

    im going to replace my consumer unit , my present one has developed a slight buzzing from main isolater breaker and im looking for one with more ways . are there any makes to avoid and whats a good make??? any help appriciated
  6. R

    quick circuit breaker question

    ive bean reducing my lighting load with led and energy saver lamps . have managed to get load done to 1.3 A with every light on indoors & outdoors . these lights are fed from three 6A mcb's should i derate them for the reduced load ???? :lol: :lol:
  7. R

    upgraded supply quote from scottish power

    had scottish power guy round today to give me a quote for upgrading incoming supply . i was quoted £2000 if i did trench to transformer 100m away and £5000 if they do whole job . im sticking with my 60A supply just need to interlock shower and heating so they are not on at same time . he...
  8. R

    electricity supply tolerances

    does anybody know what the domestic supply limits are for voltage and current . ive had a search on the web with no succsess i think my incoming cable is two small and thats causing me bad voltage drop
  9. R

    gas safety

    when i get my gas cooker installed should i get a carbon monoxide detector fitted ?? i already have smoke alarms in hall .
  10. R

    gas cooker using bottled lpg gas

    im thinking of changing my electric cooker for a gas version which i would like to run from lpg bottles . does anyone have a setup like this ?? how long does a bottle last ???
  11. R

    domestic 3 ph supply

    has anybody had a 3 ph supply installed into there property and roughly how much it costs . my house is running 60A when heating on and voltage drops to 220v its at 15A and 240v when heating off . is 60 A excessive in modern times ???
  12. R

    lpg gas supply pipe size

    my mates lpg gas boiler packed in and he has bought a 40 kw combi system and he has a large lpg cooker . the old system was running on 3/4 thick wall galv pipe from tank and 15 mm copper inside . the new boiler connection is 22mm what size pipes should he be using???
  13. R

    lights dim when ch boiler starts up

    just had a 12 kw aztec electric boiler fitted today and when it kicks in the lights dim and when it cuts out lights get brighter again . do i need a bigger incoming supply/meter/fuseboard ??????
  14. R

    morso stoves any good???

    im looking for a new stove , does anyone have a morso squirrel ?? are they any good
  15. R

    hunter herald 14 plumbing

    im having a few problems with my ch and im wanting to check plumber plumbed in in correctly , does anyone have a hunter stove with a wraparound boiler.
  16. R

    radiator's barely warm

    ive got a multifuel stove which has a water output of 13 kw ive got 9 radiators in the circuit and a hot water tank . after fire is lit and up to temperature the pipe that goes to the hot water tank gets hot and when the return to fire gets hot the radiator pump kicks in and within an hour all...
  17. R

    velux window air gap

    im building an extension and am planning to install velux windows into the roof but im concerned about the air gap after i install the window , how will the air flow over this section of roof if the window is installed ?? any ideas anybody
  18. R

    old size copper pipe

    im installing some new pipework in my bathroom can you get adapters from the old sixes to the new sizes my pipes are slightly smaller than 22mm and slightly smaller than 15mm
  19. R

    plaster board

    im planning to replasterboard my bathroom behind bath annd shower cubicle as previous owner did not beleive in grout and wall was all black , and im wanting to put insulation into the cavity do help with noise . do i need special plaster board for bathrooms???
  20. R

    mains water pressure

    ive a problem with high mains water pressure and have ordered a pressure reducing valve , but what pressure should i set it at ???