  1. arfurrrr

    Changing existing texacom bell box to pryronix deltabell E . wiring

    Hi I want to swap my old texacom bell box to a deltabell e / plus box . Attached is existing wiring for texacom And also attached is my interpretation of how the deltabell should be wired. I have to swap 2 at mine both accessed via ladder and I wanted to make I got it right 1st time...
  2. arfurrrr

    Under floor heating (wet) liquid screed

    Hi , I`ve had a couple of ideas thrown at me from some other tradesmen , non of which are tilers . One has said , just tile onto the screed (liquid version) and the other has said , there is a mat you can buy which you tile onto and then if the screed cracks the tiles don`t but what...
  3. arfurrrr

    Timber Dimensions

    Can anyone help me with the dimensions for some timber roof joists . I am building a rear extension extending 4mtrs , The overall span is 4mtrs , including 100 brick 100 cavity and 100 brick . The council said use 8 x 3 timbers , the 8" has caused a problem with the roof pitch ...
  4. arfurrrr

    combustion chamber !

    anyone else having trouble getting in ?
  5. arfurrrr

    Multimeters ref O.L

    Could you sparkies clear up a question I`m saying O.L means open loop and a few gas guys are saying it means over loaded . My fluke f179 , when set on ohms and not connected to anything says O.L , when i connect it i get a reading , a resistance . Surely when its not connected to...
  6. arfurrrr

    Vaillant VRT360 connected to ECOMAX 835 ?

    Hi , can this programmable stat be connected to the ECOMAX 835 . I`m not too sure if i`d heard it couldn`t as it was only suitable for the ECOTEC ! Many thanks , Arf .
  7. arfurrrr

    Bosch GSR10.8 10.8V Li-Ion Screwdriver

    www.screwfix.com/app/sfd/cat/pro.jsp?id=61739&ts=86834# does anyone have one of these and are they any good ? arf
  8. arfurrrr

    Radiator installation + gas fire price match !!!!

    Pricing up a job today and was asked to work everything out size of rads and gas supply pipe , submit to customer for them to go and obtain a price and if i would match it and or beat it by 10% LOL :lol: What planet are some people on I could see payment problems later down the line...
  9. arfurrrr

    outlook email question

    on my email i have the following from : to : cc : subject : since i put on the from bit (which i dont know how i did) i can`t send email it just goes into the out box but with no date so it doesn`t get sent any ideas ?
  10. arfurrrr

    new install bathroom fan / cooker extractor hood

    I know you guys would register the installation via Part P , but how many of you register the same item through Part F ?
  11. arfurrrr

    Part P test certificate

    apx 6 months ago my customer had a new CU fitted and his radial supply to his whirlpool bath protected by an RCD . He has unfortunately dropped his shower head through the bath and it needs replacing , do i need to get the supply tested again or can i connect the new bath and whirlpool into...
  12. arfurrrr

    Britony Combi 80 - Help !

    boiler : Britony Combi 80 Problem : Intermittent and varying high pitch noise coming from heat exchanger when Central Heating is on . Actions so far : spoke with Chaffoteaux , guy was very quick to diagnose blocked or partly block Main H/Ex and DHW H/Ex , removed and place in...
  13. arfurrrr

    British Gas Charging to supply PME

    fitting some new lights in a bathroom , there is no earthing at all (tt system) I have provided main bonding , sup bonding and a temp earth spike . British Gas who are the billing company for electricity have said they will charge to provide a PME connection. Is this right ? can they...
  14. arfurrrr

    Domestic CCTV

    any of you sparkys recommend any good online CCTV suppliers , want 2 cameras (external) nowt massive with IR + monitor Cheers
  15. arfurrrr

    Corgi Gas Engineer Moaning , but right to !

    Hi All , just wanted to share my frustration this morning when i attended my first job , which was to move a gas supply pipe and relocate for a new gas hob. 1st job , check suitability of hob and location . 2nd job , look at existing appliances , gas pipework and carry out a tightness test...