  1. S

    Flossy lights - rewire

    I have a twin fluorescent fitting wired in but I'd like to control each tube with a different switch. (actually I have a few of these double fittings - and I want one switch to control say the left hand tubes and another switch to control the right hand tubes). Looking inside we have...
  2. S

    Garage MCB ratings on 6mm cable

    Hi. Just wondering what is a safe MCB rating for the setup I've currently got on my garage. In house consumer unit is new & currently has a 40A MCB (non-RCD) protecting the 6mm supply to the garage. In garage, there is a second mini consumer unit (RCD protected) supplying two circuits...
  3. S

    Fluorescent startup draw

    Hi, Wondering if anyone can suggest how to calculate what can be fitted to an existing circuit. Its a 6A B6 MCB running 1.5mm t&E to the light fittings. How many 1800mm 70w tubes can I expect to run without the MCB popping / overloading the cicuit? I was hoping for up to 10! Are...
  4. S

    Fitting a 'too big' radiator

    Hi, Just wanted to know if there are any adverse side effects of fitting a radiator which is technically too big for the room? Ie if it is in a loop, would having a big beast in this room controlled by a thermostat valve mean that this room gets to temp too quickly then the valve shuts off...
  5. S

    Calculating radiator size

    In the process of redecorating our main bedroom now & replacing the woefully undersized and badly positioned radiator. Are there any calculator program type things which would help us choose the best size rad for the room? Very approximately 4m square insulated cavity walls. 2.4m window...
  6. S

    drainage channels - with pics

    Picture below shows an alley way I'm planning to brick off. It'll then be knocked through to effectively enlarge the garage to the right (in the picture). Red lines indicate where the single skin brick wall will be constructed tieing not toothing into surrounding walls. At present...
  7. S

    Garage roof - bedroom above

    Can someone give advice on building regs? I'm opening my garage out a bit by knocking a side of the garage through into a walkway which is between the old house and garage. When the garage was built, a new master bedroom was added upstairs above the walkway and garage. The wall having a...
  8. S

    Structural engineers role

    Just recieved plans back from my engineer. I'm having a 3m hole knoched in the side of my garage wall to open it up a bit. Bedroom up above so it needs a lintel fitted. One end is being supported by existing brickwork, the other with a PFC. Question is - should the engineer provide...
  9. S

    chase out dead wiring or leave in situ

    I've just disconnected a couple of wall lights in my upstairs bedroom and re-routed the wiring from up in the loft down through a central rose instead. Should I bother chasing out the old wiring from the walls or just plaster over the ends and leave the rest in situ? Its dead from both...
  10. S

    flourescent light switch

    Just a quickie: Would this be safe to use as a switch for a set (5) of under counter 10W flourescent tubes? http://www.maplin.co.uk/Module.aspx?TabID=1&ModuleNo=2363&doy=4m1 Would switch live panel mounted in an earthed steel box. Soldered & insulated terminals. If not, why not? Thanks!
  11. S

    Moving kitchen wires

    Morning chaps. Have recently taken posession of a 20s/30s property which has been extended a few years back by the previous (part time builder!) owner. The boiler was condemned a few weeks back and we've now got a nice new replacement which has also been moved out of the kitchen and into the...